IR Control

The switch can be controlled via IR using the provided IR remote or using IR via a control
system In order to use the included IR remote, an IR receiver must be purchased separately
Buttons
1
2
3
4
5
Note:
The encoding format for the above IR codes is NEC (38 KHz) Any third-party device used
for IR control of the switch must support NEC (38 KHz)

RS-232 Control

Configuration for control system serial ports can vary. Refer to the documentation for the
system in use for proper connection and configuration. Below are the parameters for RS-232
control
Important:
Devices must be connected to the inputs and outputs of the switch for RS-232
commands to execute
The command structure for RS-232 is outlined below
Function
Switch input
Example:
SET SWITCH IN1<CR> switches to input 1
You can use <CR> or <LF> to end a command All commands must end with a carriage return or
a line feed
IR Codes
Description
0x02 0x0a
Switch to the next active source input (Cycle 1-4)
0x02 0x08
Switch to the previous active source input (Cycle 1-4)
0x02 0x04
Switch to source input 1
0x02 0x05
Switch to source input 2
0x02 0x06
Switch to source input 3
0x02 0x0c
Switch to source input 4
N/A
Not available
Parameters
Baud Rate
Data Bits
Parity
Stop Bits
Flow Control
Command
Parameter
IN1<CR>
IN2<CR>
IN3<CR>
IN4<CR>
SET SWITCH
NEXT<CR>
PREV<CR>
Value
9600 bps
8 bits
None
1 bit
None
Description
Switch to source input 1
Switch to source input 2
Switch to source input 3
Switch to source input 4
Switch to the next input
(Cycle 1-4)
Switch to the previous
input (Cycle 1-4)
10
Return
1
SWITCH<CR>