Safety Notes; Transport, Storage And Packaging; Technical Data - oventrop Regumat-180 Installation And Operating Instructions For The Specialised Installer

Valves, controls + systems, boiler connection system
Table of Contents

Advertisement

Available languages

Available languages

2 Safety notes

2.1 Correct used
The product group "Regumat" is solely designed for
use in the heating sector. Acting as a link between the
heat generator and local heating circuits, it serves the
supply of heating water to radiators, a surface heating
or a storage cylinder according to requirements.
Safety in operation is only guaranteed if the boiler
connection system is used correctly.
Any use of the boiler connection system outside
the above applications will be considered as non-
compliant and misuse. Claims of any kind against the
manufacturer and/or his authorised representatives
due to damages caused by incorrect use cannot be
accepted.
The observance of the installation and operating
instructions is part of the compliance terms.
2.2 Possible dangers at the installation location
and during transport
The case of an external fire has not been taken into
consideration when constructing the boiler connection
system.
!
DANGER
Suitable measures (e.g. safety valves) have to
be taken to ensure that the maximum operating
pressures and max. operating temperatures are
not exceeded.
!
WARNING
Heavy product group!
Risk of injury! Suitable transport and lifting devices
are to be used. Wear suitable protective clothing
(e.g. safety shoes) during installation and use
safety devices. External components like
handwheels or pressure test points must not be
misused for the absorption of external forces, e.g.
as connection point for lever tools etc.
Hot or cold surfaces!
Risk of injury! Do not touch the boiler connection
system without safety gloves. It may get very hot
or cold during operation.
Sharp edges!
Risk of injury! Only touch with safety gloves.
Threads, bore holes and edges are sharp.
Small components!
Risk of ingestion! Store and install the components
of the boiler connection system out of reach of
children.
Allergies!
Health hazard! Do not touch the boiler connection
system and avoid any contact if allergies against
the used materials are known.
16
3 Transport, storage and
packaging
3.1 Extent of supply
-
Pre-assembled "Regumat" DN 25 product group
with wall bracket
-
Universal thermal insulation with ventilation grille
of modular construction; consisting of front and
rear insulation shell and insertion block suitable for
the installation of standard high-efficiency pumps.
-
Sealing set (4-fold)
-
Pump installation set (stations without pump)
3.2 Transport inspection
Upon receipt check delivery for any damages caused
during transit and for completeness.
Any damage must be reported immediately upon
receipt.
3.3 Storage
The boiler connection system must only be stored
under the following conditions:
- Do not store in open air, keep dry and free from
dust.
- D o not expose to aggressive fluids or heat sources.
- Protect from direct sunlight and mechanical
agitation.
- Storage temperature: –20°C up to +60°C
- Max. relative humidity of air: 95 %
3.4 Packaging
Packaging material is to be disposed of in an
environmentally friendly manner.

4 Technical data

4.1 Performance data
Nominal size:
Max. operating temperature
for standard pumps:
Max. operating temperature
for high-efficiency pumps:
Max. operating pressure p
Opening pressure of the
check valve:
Kvs value:
"Regumat S"
"Regumat M3"
Distance between pipe centres:
Connections:
Fluid: Non-aggressive fluids (e.g. water and suitable
water and glycol mixtures according to VDI 2035). Not
suitable for steam, oily and aggressive fluids.
DN 25
+110°C
+95°C
:
10 bar
s
20 mbar
7
5.5
125 mm
G 1½ flat sealing

Advertisement

Table of Contents
loading

This manual is also suitable for:

Regumat m3-180Regumat s-18013572701357070

Table of Contents