Bosch Rexroth IndraControl VAC 05.1 Instructions Manual page 29

Connection modules
Table of Contents

Advertisement

DOK-SUPPL*-VAC*XX.X***-IT01-EN-P
Rexroth IndraControl VAC 05.1, VAC 30.2, VAC 31.1 Connection Modules
Cross sections depending
on the power demand; at .
2
least: 4mm . In case of
higher power demand:
2
2x4 mm
VAC connection module
(DC 24V)
X1. 1
PE
Easily removable and visible.
PE bars are to be installed preferably on the mounting plate. In case
of isolated PE bars, both ends are to be connected to the mounting
plate by means of copper strips with a maximum length of 20 cm. The
cross-section of the copper strips has to be at least equal to that of the
incoming mains cable.
0.75 mm
2
, up to 6 m and 1.5 mm
power supply unit is required!
Polarity reversal of the X1.1 connector might destroy the operator ter‐
minal, if there is no additional external protection (fire hazard). The
reason for this is the grounding of the 0 V in the operator terminal and
simultaneously to that the grounding of the 0 V load (PELV).
Fig.10-7:
Limit values of the DC 24 V voltage
WARNING
Supply the device only with voltage sources that feature protective ex‐
tra-low voltage (e.g. SELV or PELV according to EN 61131-2).
Connect only voltages and circuits to connectors, terminals and interfa‐
ces up to 50 V nominal voltage that ensure safe isolation to dangerous
voltages (e.g. by sufficient isolation and electric strength).
NOTICE
The DC 24 V power supply of the hand-held terminal has to be fused appro‐
priately in the end application! The max. allowed fuse is 2 A.
Bosch Rexroth AG
Assembly, Disassembly and Electrical Installation
L2 L3
L1
PE
Power supply unit
with insulated trans-
former acc. to EN 60742
10 mm
DC 24V
2
(blue)
Max. length 4 m
6 mm
1
A
A
Grounding rail
24 V load
0 V load
A = Terminal blocks 4 mm
B = Terminal blocks 10 mm
Cross sections depending on
the power demand; at least
2
0.75 mm
3
1
E.g.
Terminal block UK6-FSI/6 with
Safety cutout TCP2.0 A by PHOENIX CONTACT
2
Pin 1
Pin 2
Pin 3
PLC
2
, up to 10 m. From 10 m, a separate
Danger to life due to electric shock!
Fire hazard due to defective components!
27/49
PE
2
(green/yellow)
B
2
10 mm
(green/yellow)
2
2
2
: Insulated terminals
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents