Maintenance Instructions MI-137 Revision A RL Series Relief Valve Spring Acquisition The valve is shipped assembled complete less the adjustment cap and the lock nut. Springs can be acquired by ordering the appropriate kit. Spring kits are as follows: Spring Pressure Range...
Page 2
O-ring and back-up ring). 3. Place the O-ring or O-ring/Back-up ring into the groove provided for it. Gently slide the o-ring over the mandrel in this direction Lower Stem Assembly Body Bonnet Assembly Parker Hannifin Corporation Instrumentation Valve Division Jacksonville, Alabama...
Page 3
Cap. 13. If the valve has a Manual Upper Stem, thread the Handle onto it. Figure 4: RL Series Relief Valve with Manual Override Exploded View Setting Desired Cracking Pressure 1. Rotate the Cap to set the desired cracking pressure.
Page 4
Normal make-up for US Customary port sizes 4 thru 16 (1/4 thru 1 inch) and SI port sizes 5 thru 25 (5 thru 25 mm) is 1 1/4 turn from finger tight. For larger port sizes consult Parker Ferrule Presetting Tool Instructions.
Page 5
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. ALL PARKER VALVES MUST PASS A RIGID OPERATIONAL AND LEAKAGE TEST BEFORE LEAVING THE FAC- TORY.