Hisense AVWT-76FKFSHA Technical Handbook page 2

Vrf air-conditioner (heat recovery)
Hide thumbs Also See for AVWT-76FKFSHA:
Table of Contents

Advertisement

Dear user:
Thank you for choosing and using our products. For your better understanding and use of this product, be sure to read and
comply with the following matters before use
Signal words (danger, warning and caution) are used to identify levels of hazard seriousness. Definitions for identifying
hazard levels are provided below with their respective signal words:
DANGER
WARNING
CAUTION
NOTE
This manual should be considered as a permanent part of the air conditioning equipment and should remain with the air
conditioning equipment.
This manual gives a common description and information for this heat pump air conditioner which you operate as well for other
models.
HISENSE pursues a policy of continuing improvement in design and performance of products. The right is therefore reserved to vary
specifications without notice.
HISENSE cannot anticipate every possible circumstance that might involve a potential hazard. This heat pump air conditioner is
designed for standard air conditioning only. Do not use this heat pump air conditioner for other purpose such as drying clothes,
refrigerating foods or for any other cooling or heating process. Do not install the unit in the following places. It may cause a fire,
deformation, corrosion or failure.
Places where oil (including machinery oil) sprays
*
Places where inflammable gas may generate or flow.
*
Do not install the unit in the place where silicon gas drifts. If the silicon gas attaches to the surface of heat exchanger, the fin surface
repels water. As a result, drain water splashes outside of the drain pan and splashed water runs inside of electrical box. In the end,
water leakage or electrical devices failure may occur.
Do not install the unit in the place where the breeze directly catches the animals and plants. It could adversely affect the animals and
plants.
Installation and service engineering must comply with local standards, laws and regulations.
As the"public inaccessible appliances", the indoor units are required to be installed at a height of no lower than 2.5m.
The installation of the air conditioner can only be carried out by dealer or professional, and self installation by user may cause water
leakage, electric shock or fire.
If you have any questions, contact your dealer or designated service center of HISENSE.
To prevent the environment, please do not discard the product at will, and HISENSE can provide recycling services in accordance
with the relevant provisions of the country and provide replaceable parts in accordance with national standard requirements.
This heat pump air conditioner has been designed for the following temperatures. Operate the heat pump air conditioner within this
range.
Indoor Unit-Cooling
Indoor
32 DB/23 WB
Outdoor
Indoor Unit-Heating
Indoor
Outdoor
Water Module Cooling
Inlet water
Outdoor
Water Module Heating (Floor Heating)
Inlet water
Outdoor
Water Module Heating (DHW)
Inlet water
Outdoor
IMPORTANT NOTICE
: A hazardous situation which, if not avoided, should result in death or serious injury.
: A hazardous situation which, if not avoided, could result in death or serious injury.
: Used with the safety alert symbol, indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
:Useful information for operation and/or maintenance.
Maximum
Minimum
21 DB/15 WB
52 DB *
-10 DB
Maximum
Minimum
27 DB
15 DB
16.5 WB
-25 WB**
Maximum
Minimum
25
10
48 DB
10 DB
Maximum
Minimum
54
10
16.5 WB
-25 WB**
Maximum
Minimum
54
10
43 WB
-25 WB**
Places where a lot of sulfide gas drifts such as in hot spring.
*
Places where strong salty wind blows such as coast regions,or
*
places with an atmosphere of acidity or alkalinity.
(℃)
DB: Dry Bulb, WB: Wet Bulb
(*) 48℃ DB ~ 52℃ DB, Operation Control Range
(**) -20℃ WB ~ -25℃ WB, Operation Control Range
I

Hide quick links: