Capacity
Model
Combination
Power Supply
Nominal Capacity
Cooling Operation
Power Consumption
EER
Capacity (Max)
Power Consumption (Max)
COP (Max)
Heating Operation
Capacity (Nom)
Power Consumption (Nom)
COP (Nom)
Sound Pressure Level
※1
Height
Outer Dimensions
Width
Depth
Height
Packing Dimensions
Width
Depth
Cabinet Color
Net Weight
Gross Weight
Air Flow Rate
Type
Brand
Refrigeration Oil
Charge (Total)
Refrigerant Charge Before Shipment
Refrigerant Flow Control
Heat Exchanger Type
Compressor Quantity
Condenser Fan Quantity
Low Pressure Gas Line
Heat Recovery
High/Low Pressure Gas Line
Operation System
Liquid Line
High/Low Pressure Gas Line
Heat Pump
Operation System
Liquid Line
Hole for Power Supply Wiring
Hole for Control Line Wiring
The above cooling and heating capacities show the capacities when the outdoor unit is operated with the 100% rating of indoor units,
Cooling Operation Conditions
Indoor Air Inlet Temperature:
Outdoor Air Inlet Temperature: 35
Piping Length: 7.5 meters, Piping Lift: 0 meter
※ 1: The sound pressure is tested according to the appendix B of EN14511. The above parameters were measured in an
anechoic chamber with no echo, so the echo should be considered in the field. When return air grille is on bottom plate of the
duct or external static pressure is higher, the sound pressure will increase according to the installation method and building
structure.
16HP
AVWT-154FKFSHA
AVWT-154FKFSHA
kW
45.0
kBtu/h
153.5
kW
11.22
-
4.01
kW
50.0
kBtu/h
170.6
kW
11.88
-
4.21
kW
45.0
kBtu/h
153.5
kW
10.23
-
4.40
dB(A)
62
mm
1730
mm
1350
mm
750
mm
1930
mm
1420
mm
790
-
kg
369
kg
393
3
267
m
/min
-
-
L
8.4
Kg
9.8
-
-
-
2
-
2
mm
Φ28.60
mm
Φ22.2
mm
Φ12.70
mm
Φ28.60
mm
Φ12.70
mm
46
mm
20
o
27℃ DB (80
F DB)
19℃ WB (66.2°F WB)
o
o
C DB (95
F DB)
18HP
AVWT-170FKFSHA
AVWT-170FKFSHA
-
-
-
-
-
-
AC 3Φ,380-415V/50/60Hz
50.0
170.6
12.69
3.94
56.0
191.1
13.97
4.01
50.0
170.6
11.88
4.21
62
1730
1350
750
1930
1420
790
Ivory White
377
401
296
FVC68D
Idemitsu Kosan
8.4
10.6
Micro-Computer Controlled Expansion Valve
Multi-Pass Cross-Finned Tube
2
2
Φ28.60
Φ22.2
Φ15.88
Φ28.60
Φ15.88
46
20
Heating Operation Conditions
Indoor Air Inlet Temperature:
Outdoor Air Inlet Temperature:
38
20HP
22HP
AVWT-190FKFSHA
AVWT-212FKFSHA
AVWT-190FKFSHA
AVWT-212FKFSHA
-
-
-
-
-
-
56.0
61.5
191.1
209.8
14.36
16.62
3.90
3.70
63.0
69.0
215.0
235.4
15.75
18.11
4.00
3.81
56.0
61.5
191.1
209.8
13.40
15.73
4.18
3.91
63
64
1730
1730
1600
1600
750
750
1930
1930
1665
1665
790
790
400
401
426
427
350
350
8.6
8.6
11.5
11.5
2
2
2
2
Φ28.60
Φ28.60
Φ22.2
Φ25.4
Φ15.88
Φ15.88
Φ28.60
Φ28.60
Φ15.88
Φ15.88
46
46
20
20
o
o
20
C DB (68
F DB)
o
o
7
C DB (45
F DB)
o
o
6
C WB (43
F WB)