Page 1
Power Source AVC-05URCSAB AVC-07URCSAB AVC-09URCSAB 220-240V AVC-12URCSAB /50HZ Compact AVC-14URCSAB 4-Way AVC-17URCSAB Cassette Type AVC-07UR2SAB AVC-09UR2SAB 220V AVC-12UR2SAB /60HZ AVC-14UR2SAB AVC-17UR2SAB 1080677 P00982Q ORIGINAL INSTRUCTIONS...
Page 3
Manufacturing number and manufacturing year: refer to model Nameplate. Notes: This declaration becomes invalid, if technical or operational modifications are introduced without the manufacturers consent. Hisense Italia S.r.l. is authorised to Compile the Technical Construction File. Ad. : Via Montefeltro 6A, 20156 Milano. Name, Surname Position/ Title...
To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. Hisense's Hisense's...
Page 9
The appliance is not to be used by children or person with reduced physical, sensory or mental capabilities,or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised that they do not play with the appliance.
Page 11
Regarding the instructions of Wired Remote Control Switch or Wireless Remote Control Switch,read the operation manual attached to the control switch.
Page 16
Fan Motor Speed-up Setting so that uniform air distribution is available. 285mm...
Page 18
15 to 20 15 to 20 (1) Removing Air Intake Grille from Air Panel Step 1 Open the air intake grille to an angle of approximately 45 from the surface of the air panel as shown in Fig. 4.9. Air Panel Air Intake Grille Use the Pattern Board is in the packing...
Page 19
(2) Installing Air Panel Step 1 Four fixing positions will be seen after removing air l If the screws are tightened insuficiently, it may intake grille from air panel. cause of the failure. Set the corner of the electrical box of the indoor unit to the position of wireless receiver corner of the air panel.
Page 20
NOTE 1) The adequate air flow direction may be different depending Check the wiring connections securely after wiring work. on the conditions such as: If some problems are existing at the wiring connections, • Air Conditioner’s Installation Position it may cause a fire. •...
Page 21
Fig.4.3 and Fig.4.6.(Indoor Unit) Flaring Dimension Perform the flaring work as shown below. Diameter -0.4 R410A R407C 6.35 9.53 13.2 13.0 12.7 16.6 16.2 15.88 19.7 19.4 19.05 23.3 (*)It is impossible to perform the flaring work with 1/2H material. In this case, use an accessory pipe(with a flare).
Page 24
Noise level will increase 2-3db(A) by Speed-up Setting(SHi) 220-240V /50HZ 220V /60Hz Fan Motor Speed-up Setting(SHi) To be adapted for high ceiling installation Speed-up Setting(SHi) is required .Before shipment normal fan speed (Hi) is connected. To shift to SHi setting Connect cable terminal of SHi to the power line of fan motor.
Page 25
Power Maximum EN60 335-1 EN60 335-1 Source Current 0.53A 05 12 220-240V /50Hz 2.5mm 0.75mm 0.59A 220V /60Hz 0.75A The wire sizes marked with *1 in the above table are selected at the maximum current of the unit according to the European Standard, EN60335-1.Use the wires which are not lighter than the ordinary polyvinyl chloride sheathed flexible cord (code designation H05VV-F).
Page 26
Ex.) Set at No.5 Cycle Set by inserting Setting DSW5 Slotted screwdriver Position into the groove Set All Pins OFF Before shipment. DSW5 and RSW2 are set to "0". RSW2 Max.64 cycles are available to set when all the equipment to be connected are corresponding to Hi-NET.
Page 28
Qingdao Hisense Hitachi Air-conditioning Systems Co., Ltd. Add: No. 218, Qianwangang Road, Economic & Technical Development Zone, Qingdao, P.R. China P00982Q 2017.12.21...