Run Test:
1.
Tap the RESULTS button.
2.
Tap the START/STOP button to start the test. After auto-configuration, the OTDR will perform a
connection check to ensure that the connection is Good. If the Connection is Bad, repeat steps 1 through 7
on page 2. Also, inspect and clean the fiber end faces in any patch panels or connectors near the OTDR.
3.
The OTDR will perform acquisitions at the configured wavelengths. Results may be displayed in 3 different
formats: Trace view with Summary, Trace view with events, or Smartlink view.
Tap the Trace/Smartlink soft key to toggle between Trace views and SmartLink view.
Tap the Enter button in the center of the arrow buttons to toggle between the
Trace view with Summary and Trace view with Events:
a. Trace view with Summary: Results for each wavelength
are shown in different colors in the upper results display.
Fiber length and link loss are shown in the lower display.
Use the right and left arrow buttons to toggle
between results for each wavelength.
b. Trace view with Events: Results for each wavelength
are shown in different colors in the top of the display.
Each event is listed in the lower display. Events that
violate pass/fail alarm thresholds are shown in RED.
Use the right and left arrow keys to toggle between
results for each wavelength.
Tap the Zoom soft key to enable the following
controls:
c. SmartLink view: The FUT is displayed as a series of icons
representing each event (connectors, splices, splitters,
bends, etc.). The center of the display shows summary
results per wavelength for the entire span. Acquisitions
for which all events are acceptable are marked with a
green check
pass/fail thresholds for loss or reflectance are marked
with a red
exceeds thresholds.
Tap an event icon and tap the Event View soft
key to show detailed results for the event.
Contact Us
+1 844 GO VIAVI
(+1 844 468 4284)
Toggle between auto zoom and full trace view.
Expand and contract trace.
. Acquisitions with events that exceed
. The lower display shows each event that
To reach the VIAVI office nearest you,
visit viavisolutions.com/contacts.
VIAVI Solutions
Figure 9: Trace view with Summary
Figure 10: Trace view with Events
Figure 11: SmartLink View