Controller connection (command) cable (except for SSCNET III
cable) (3)
If controller and servo amplifier are in the same cabinet
Use a shielded twisted pair cable, and ground it on both sides of the controller and servo amplifier with P clips or U clips.
When the cable length is 2 m or less, ground the cable on the controller side.
Cabinet
As close as
possible
Controller
If controller or others is in the different cabinet from servo amplifier
Use a shielded twisted pair cable, and ground it on both sided of the controller or others and servo amplifier with P clips or U
clips.
Cabinet
Controller, etc.
3 EMC COUNTERMEASURES
16
3.4 Cable layout
As close as
possible
Shield twisted pair cable
10 cm or less
10 cm or less
Shield twisted pair cable
Servo
amplifier
Cabinet
Servo
amplifier

Advertisement