Error No
E3026
E4040
E5300
E5301
E5302
E5303
E5304
Table 8-1: CLARiTY Error Messages (Continued)
8-16
CLARiTY Error messages
Report on CLARiTY Operator Interface
'External Error' - The operation of the printer has been
suspended by the control system. If the Clear button is
available below, you may touch it to clear this error and
resume printing.
'Allowed Login Attempts Exceeded' - A user enter an
incorrect password repeatedly and has been disabled.
'Printhead Volts Error' - The Printhead volts are outside
the working range.
Power off and disconnect all printhead connections.
Power back on and check whether the fault persists.
If it does then there is a problem with an internal PCB. If
it does not then there is a short in a printhead or the
interconnecting cable.
Contact your local maintenance engineer or service
representative for further support.
'Group %2 Print Queue Overflow' - Group %2 has
detected more than five products between the print
sensor and the printhead. This may be due to pack
spacing or false sensor triggers, or a faulty sensor.
Touch the "Clear" button below to clear this fault
message and then try to resume printing.
If the problem persists, call your maintenance engineer
or local service representative.
'Group %2 Not Ready' - Group %2 has been triggered
to begin printing on a new product before completing the
print for the previous product.
This could be due to inadequate product spacing or
false print sensor triggers, or incorrect fixed speed
setting (if you are running in fixed speed mode, without
a conveyor speed encoder), or a faulty print sensor or
faulty printhead.
Touch the "Clear" button below to try and resume
printing.
If the problem persists, call your maintenance engineer
or local service representative.
'Group %2 Print Signal Ignored' - The number of
consecutive ignored print signals by Group %2 has
exceeded the defined limit. Please check that prints are
being triggered correctly and that the selected job fits
the product.
Touch the "Clear" button below to dismiss this error.
'Printhead Power Supply' - An open circuit fault has
been detected in the printhead power supply.
Power the printer off and on to resume printing.
If the problem persists, call your maintenance engineer
or local service representative.
Status
Fault
Warning
Fault
Fault
Fault
Fault
Fault
Rev AB

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the m600 Universal and is the answer not in the manual?

Related Products for wolke m600 Universal

Table of Contents

Save PDF