Huawei PDU8000 User Manual page 139

Modular precision pdc
Hide thumbs Also See for PDU8000:
Table of Contents

Advertisement

PDU8000 Modular Precision PDC V2.0
User Manual
Fuse No.
1FU7/2FU7
1FU8/2FU8
1FU9/2FU9
1FU10/2FU1
0
1FU11/2FU1
1
1FU12/2FU1
2
1FU13/2FU1
3
1FU14/2FU1
4
1FU15/2FU1
5
Issue 04 (2021-04-13)
Function
Voltage sampling fuse of phase L3 on the power board to the
right of the first output subrack (cabinet rear view)/Voltage
sampling fuse of phase L1 on the power board to the left of the
first output subrack (cabinet rear view)
Voltage sampling fuse of phase L2 on the power board to the
right of the first output subrack (cabinet rear view)/Voltage
sampling fuse of phase L2 on the power board to the left of the
first output subrack (cabinet rear view)
Voltage sampling fuse of phase L1 on the power board to the
right of the first output subrack (cabinet rear view)/Voltage
sampling fuse of phase L3 on the power board to the left of the
first output subrack (cabinet rear view)
Voltage sampling fuse of phase L3 on the power board to the
right of the second output subrack (cabinet rear view)/Voltage
sampling fuse of phase L1 on the power board to the left of the
second output subrack (cabinet rear view)
Voltage sampling fuse of phase L2 on the power board to the
right of the second output subrack (cabinet rear view)/Voltage
sampling fuse of phase L2 on the power board to the left of the
second output subrack (cabinet rear view)
Voltage sampling fuse of phase L1 on the power board to the
right of the second output subrack (cabinet rear view)/Voltage
sampling fuse of phase L3 on the power board to the left of the
second output subrack (cabinet rear view)
Voltage sampling fuse of phase L3 on the power board to the
right of the third output subrack (cabinet rear view)/Voltage
sampling fuse of phase L1 on the power board to the left of the
third output subrack (cabinet rear view)
Voltage sampling fuse of phase L2 on the power board to the
right of the third output subrack (cabinet rear view)/Voltage
sampling fuse of phase L2 on the power board to the left of the
third output subrack (cabinet rear view)
Voltage sampling fuse of phase L1 on the power board to the
right of the third output subrack (cabinet rear view)/Voltage
sampling fuse of phase L3 on the power board to the left of the
third output subrack (cabinet rear view)
NO TE
● The preceding tables use a fully configured PDC as an example. The actual cabinet
configurations prevail.
● *FU*-1 indicates the fuse input end, and *FU*-2 indicates the fuse output end.
Copyright © Huawei Technologies Co., Ltd.
8 Maintenance Guide
132

Advertisement

Table of Contents
loading

Table of Contents