Axis P5655-E User Manual page 25

Ptz network camera
Table of Contents

Advertisement

AXIS P5655-E PTZ Network Camera
Specifications
Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by
the VAPIX® Application Programming Interface or from the product's webpage.
Digital input — For connecting external devices that can toggle between an open and closed circuit, for example
PIR detectors, door/window contacts, and glass break detectors.
Function
0 V DC (-)
DC output
Configurable (Input
or Output)
1
0 V DC (-)
2
DC output 12 V, max 50 mA
A
I/O configured as input
B
I/O configured as output
Axis 10-pin push-pull system connector (sold separately)
When connecting external equipment to the Axis product, an Axis 10-pin Push-Pull System Connector (sold separately) is required in
order to maintain the product's IP rating.
Mounting the wires requires a crimp tool. To get detailed mounting instructions of the wires, go to axis.com/support.
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–6
Digital input – Connect to pin 1 to activate, or leave
floating (unconnected) to deactivate.
Digital output – Internally connected to pin 1 (DC
ground) when active, and floating (unconnected) when
inactive. If used with an inductive load, e.g. a relay, a
diode must be connected in parallel with the load, for
protection against voltage transients.
25
Specifications
0 V DC
12 V DC
Max load =50 mA
0 to max 30 V DC
0 to max 30 V DC, open
drain, 100 mA

Advertisement

Table of Contents
loading

Table of Contents