Help Yourself In Case Of Faults - Meiko WS 125 M Translation Of Original Operating Instructions

Table of Contents

Advertisement

16

Help yourself in case of faults

9648649
Optional drying
Drying begins after finishing the fresh water rinsing and the dripping phase. In this pro-
cess, heated fresh air as well as air drawn from the room is blown directly onto the trolley.
This removes the majority of the water.
Machine design
The machine casing, tanks and cladding are made from 1.4301 grade (type 304) stain-
less steel.
Double-wall insulation
The machine's chambers have double walls with intermediate insulation to reduce the
noise level and the amount of heat which is radiated from the machine. The cavity is 40
mm wide in the region of the chambers.
Voltage data
See electrical wiring diagram
The machine is installed ready for connection to the power supply and operation The indi-
vidual circuits are protected against short-circuits, over-load and single-phase operation.
The operating state is identified by pilot lamps or the touch panel.
The machine control is via a programmable logic controller (PLC control).
Malfunction:
Machine does not fill!
Malfunction:
Final rinse does not spray!
Malfunction:
Vapours drain!
Remedy
 No water present
 Dirt trap clogged
 Level electrode / float valve soiled
 Solenoid valve faulty
 Suction or pressure pump defective
Remedy
 No water present
 Dirt trap clogged
 Solenoid valve faulty
 Pump for pumping water from the machine cistern
broken down
 Final rinse system is scaled
Remedy
 Suction system has failed
 Temperatures too high
 Wash arms, drying nozzles, air guide plates bent or
not correctly inserted
22 / 32