Ibex-RT-310 and -320 Series
EN 50155 WLAN 3x3 Client/Bridge/Access Point

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ibex-RT-310 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Westermo Ibex-RT-310 Series

  • Page 1 Ibex-RT-310 and -320 Series EN 50155 WLAN 3x3 Client/Bridge/Access Point...
  • Page 2: Table Of Contents

    Factory Reset Procedure..................17 Dimensions ........................17 Installation ...........................18 Mounting ........................18 Earth Connection......................19 Connection of Cables .....................19 Cooling .........................19 Replacement of Product ....................21 Specifications ........................23 Interface Specifications....................23 Type Tests and Environmental Conditions ...............25 Abbreviations and Terms ......................27 Revision Notes........................28 Westermo Network Technologies...
  • Page 3 Ibex-RT-310 and Ibex-RT-320 Series User Guide Westermo Network Technologies...
  • Page 4: General Information

    Westermo reserves the right to revise this document or withdraw it at any time without prior notice. Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
  • Page 5: Safety And Regulations

    No personal injury Minor damage to the to avoid misuse of the product product, confusion or misunderstanding NOTICE Used for highlighting general, No personal injury Minor damage to the but important information product NOTE Table 1 Warning levels Westermo Network Technologies...
  • Page 6: Safety Information

    For Ibex products, outdoor installation is allowed. During installation, ensure a protective earthing conductor is first connected to the protective earthing terminal. Westermo recommends a cross-sectional area of at least 4 mm Upon removal of the product, ensure that the protective earthing conductor is disconnected last.
  • Page 7 CAUTION - CABLE TEMPERATURE RATING There may be a requirement on the minimum temperature rating of the cable to be connected to the field wiring terminals, see Interface Specifications. Westermo Network Technologies...
  • Page 8: Care Recommendations

    If the product is used in a manner not according to specification, the protection provided by the equipment may be impaired. If the product is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo technical support.
  • Page 9: Compliance Information

    EN 45545-2, Requirements for fire behaviour of materials and components on railway vehicles • NFPA 130, Fire protection and life safety requirements for fixed guideway transit and passenger rail systems Table 2 Agency approvals and standards compliance Westermo Network Technologies...
  • Page 10: United States - Fcc

    L’exploitation est autorisée aux deux conditions suivantes: • l’appareil ne doit pas produire de brouillage. • l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Westermo Network Technologies...
  • Page 11: Europe - Simplified Declaration Of Conformity

    This product contains the IC Certification numbers 9301A-103902DT50 2.5.5 Europe - Simplified Declaration of Conformity Hereby, Westermo declares that this product is in compliance with applicable EU directives and UK legislations. The full EU declaration of conformity and other detailed information is available at www.westermo.com/support/product-support.
  • Page 12: Product Description

    Ethernet Figure 3 Ibex-RT-310 and Ibex-RT-320 block diagram The Westermo configuration management tool, WeConfig, can be used for discovery and basic configuration and maintenance. The configuration can be done via SNMP or via WebGUI. The status information is available in local LED status indicators, and through SNMP/WebGUI.
  • Page 13: Hardware Overview

    Gigabit Ethernet ports X1 and X2 Protective earth terminal Power input DC Front side label Warning symbol for surface temperatures above +60°C Antenna ports A1 to A3 Figure 4 Location of interface ports and LED indicators 3.3.2 Front Side Label Westermo Network Technologies...
  • Page 14: Rear Side Label

    WW = Manufacturing Week Serial number Article number AAAA-AAAARR AAAA-AAAA = Article number RR = Region code Figure 5 Front side label content 3.3.3 Rear Side Label Figure 6 Rear side label content 3.3.4 Interface Ports View Westermo Network Technologies...
  • Page 15: Connector Information

    X1 / X2 In / Out In / Out In / Out In / Out In / Out In / Out In / Out In / Out Housing Shield Chassis of product (ground) Table 5 Ethernet connection Westermo Network Technologies...
  • Page 16: Antenna Ports

    Any unused antenna ports must be properly terminated with 50-Ohms, otherwise the device might be damaged when power is applied to a non-terminated antenna port. NOTE To ensure specified IP protection, suitable QMA connectors / cables and terminations must be used. Westermo Network Technologies...
  • Page 17: Led Indicators

    Remove factory reset adapter within 15 seconds Successful initiation of the factory reset is indicated by blinking ORANGE OPR LED and RED ERR LED Table 9 Factory reset procedure 3.7 Dimensions Dimensions are stated in mm and are regardless variants. Westermo Network Technologies...
  • Page 18: Installation

    NOTE For indoor installation consider additional protection against dust to ensure proper heat dissipation. NOTE For outdoor installation consider additional protection against sun radiation, dust and dirt to optimize ambient temperature range. Westermo Network Technologies...
  • Page 19: Earth Connection

    This product has no replaceable fuse and should be connected via an external fuse for protection. 4.4 Cooling This unit uses convection cooling. It is recommended to install the product in areas where the natural convection airflow is not blocked and that there is enough spacing around the device. Westermo Network Technologies...
  • Page 20 Figure 11 Installation with natural convection airflow When operating the device at high ambient temperatures, it is recommended to mount the device to a metallic base plate to improve the heat dissipation. The base plate increases the surface to spread the heat. Westermo Network Technologies...
  • Page 21: Replacement Of Product

    Disconnect all cables and unscrew the product from the wall. Mount the replacement product and reconnect all cables, observing the instructions in Connection of Cables. MTTR (Mean Time To Repair), i.e. time for replacement of product is: < 10 minutes. Westermo Network Technologies...
  • Page 22 Be aware of that the surface of this product may become hot. When it is operated at high temperatures, the external surface may exceed Touch Temperature Limit according to the product's relevant electrical safety standard. This product complies with Touch Temperature Limits throughout its operational temperature range. Westermo Network Technologies...
  • Page 23: Specifications

    Shielded cable CAT5e or better is recommended Conductive chassis Table 12 Ethernet Specification NOTE The product is to be connected to internal Ethernet networks without exiting a facility and being subjected to TNVs. Recommended external supply current capability for proper startup Westermo Network Technologies...
  • Page 24 NOTICE Unused antenna port must be terminated with 50-Ohm terminations. NOTICE To avoid damages on the antenna interfaces, ensure that the far end side of the antenna cable and/or the antenna itself is connected to protective earth. Westermo Network Technologies...
  • Page 25: Type Tests And Environmental Conditions

    DC power port > 100 MOhm to all other ports Dielectric strength EN 50155 DC power port Ibex-RT-310/320-LV: 750 VDC, 60 s to all other ports Ibex-RT-320-HV: 2250 VDC, 60 s Table 14 EMC and electrical conditions Westermo Network Technologies...
  • Page 26 The power and Ethernet cables need to be fastened 200 mm or closer to the unit. The same recommendation applies to the Antenna cables Provided all connectors are connected with IP66 cabling or fitted with protective caps (delivered with the unit) and tightened to the specified torque Westermo Network Technologies...
  • Page 27: Abbreviations And Terms

    Telephone Network Voltage Serial Number SNMP Simple Network Management Protocol Virtual Private Network WebGUI Web Graphical User Interface WeConfig Westermo Configuration Tool WEEE Waste Electrical and Electronics Equipment WLAN Wireless Local Area Network Table 16 Abbreviations and terms Westermo Network Technologies...
  • Page 28: Revision Notes

    Ibex-RT-310 and Ibex-RT-320 Series User Guide 7 Revision Notes Revision Date Rev. D 2021-03 Product illustrations updated to blue, text in illustrations removed, Westermo address updated, chapter 2.5.5 updated Westermo Network Technologies...
  • Page 29 REV. D 6623-2270 2021-03 Westermo Network Technologies AB, Sweden...