For use with systems with no filter
ATTENTION!
These instructions are for Symphony Series dispensers only.
Instructions for sanitizing Symphony Plus dispensers are located
on the reverse side of this document.
Description
Periodic cleaning/descaling and sanitizing of Follett's ice and water dispenser and ice machine system is required
to ensure peak performance and delivery of clean, sanitary ice. Immediately perform Cleaning/Sanitizing procedure
(according to instructions shipped with dispenser) when this Pressurized Water Sanitizing procedure is completed.
If you experience any problems during the installation process, please call Follett Technical Service toll-free at
(877) 612-5086 or +1 (610) 252-7301 for assistance.
Materials Required
§ (1) 1.5 Gallon (or larger) plastic bucket
§ Sanitary gloves
§ Safety glasses
§ 1.6 fl. oz of Nu-Calgon IMS-II Sanitizer (P/N 00979674 - 16 fl. oz bottle)
Materials Supplied
(1) Pre-filter bowl
(1) Filter head and bracket
(1) Dip tube
(1) 3/8" ID john guest tubing, 12' (3.6 m)
(2) 1/2" NPT x 3/8" john guest fitting
(1) 3/8" to 3/8" compression fitting
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com
Symphony™ Pressurized Water
Sanitizing Kit
P/N 01089580
Instructions for Symphony only
Order parts online:
www.follettice.com
01089820R01

Advertisement

loading
Need help?

Need help?

Do you have a question about the Symphony 01089580 and is the answer not in the manual?

Questions and answers

Summary of Contents for Follett Symphony 01089580

  • Page 1 Description Periodic cleaning/descaling and sanitizing of Follett’s ice and water dispenser and ice machine system is required to ensure peak performance and delivery of clean, sanitary ice. Immediately perform Cleaning/Sanitizing procedure (according to instructions shipped with dispenser) when this Pressurized Water Sanitizing procedure is completed.
  • Page 2 § Wear rubber gloves and safety goggles (or face shield) when handling cleaner or sanitizer mixtures. § Use only Follett approved cleaners. § It is a violation of Federal law to use Sanitizing solution in a manner inconsistent with its labeling.
  • Page 3 6. Mix a 200 ppm active quaternary sanitizing Fig. 3 solution of 1 gal. (3.8 L) 100 F (38 C) water and 1.6 oz (47 ml) Nu-Calgon IMS-II Sanitizer (P/N 00979674). Fill pre-filter bowl to just below the o-ring with sanitizing solution (Fig. 3). 8.
  • Page 4 9. Turn ON water supply. Fig. 5 10. Plug in dispenser. 11. Dispense 3 cups (24 oz) of water into a container (Fig. 5). Sanitizer will fill the dispenser water lines. Note: Maximum length of water line between dispenser and filter system must not exceed 30 ft. (9 m).
  • Page 5 17. Unplug unit and allow sanitizer to remain in Fig. 7 water lines and water reservoir for at least 5 minutes. 18. Turn OFF water supply. 19. Depress red pressure release button to relieve pressure. 20. Remove pre-filter bowl (Fig. 7.1), discard sanitizer (Fig. 7.2), rinse with potable water, and re-install (Fig. 7.3).
  • Page 6 Follett is a registered trademark of Follett Corporation, registered in US. 801 Church Lane • Easton, PA 18040, USA 01089820R01 Toll free (877) 612-5086 • +1 (610) 252-7301 © Follett Corporation 6/15 www.follettice.com...