Page 2
™ GROMELLE ™ There’s a certain energy at Eaton. It’s the power of integrating the competencies of some of the world’s most respected names to build a brand you can trust to meet every power management need. The energy created supports our commitment to powering business worldwide.
Page 3
Knowing what’s important to our customers and integrating that knowledge into the fabric of our business • Eaton experts offer efficient product and application • …to deliver innovative, quality products training • …to respond fast •...
130 lb. in. C - Port connections in line 155 lb. in. 185 lb. in. D - Cover port 90˚ clockwise from body port. 220 lb. in. 255 lb. in. 300 lb. in. EATON Vane Motors M-2740-S June 2011...
O-ring Cover Port Teflon Ring Body Port Vane Spring Hub Adaptor Drain Bushing Cover Shaft Seal Pressure Plate Ring Rotor Shaft Felt Wiper Body Pressure Plate Bearing Figure 1. Cutaway View of Vane Motor. EATON Vane Motors M-2740-S June 2011...
Thus, the vanes are balanced hydraulically Clockwise Drain Rotation and are held out against the ring by a combination of spring Clockwise tank and centrifugal forces. Rotation tank Figure 2. Figure 2. EATON Vane Motors M-2740-S June 2011...
Proper coupling alignment is essential to prolong motor life. • Indirect Drive. Belt, chain and gear drives can be used with certain models of these motors. Specific recommendations and data on limitations should be obtained from a Vickers sales engineer. EATON Vane Motors M-2740-S June 2011...
5. Proper oil filling and servicing of filters, breathers, reservoirs, etc., cannot be overemphasized. 6. Good system and reservoir design will insure that aeration of the oil is kept to a minimum. EATON Vane Motors M-2740-S June 2011...
Cover Port 90 Counterclockwise from Body Port Body Port at 6 o’clock Position Port Connections In Line Body Port at 9 o’clock Position Cover Port 90 Clockwise from Body Port Body Port Cover Port Figure 6. EATON Vane Motors M-2740-S June 2011...
1. All hydraulic connections must be kept tight. A loose connection in a pressure line will permit the fluid to leak out. Loose connections in other lines can permit air EATON Vane Motors M-2740-S June 2011...
Page 12
Install new seals and o-rings. Motor shaft continuing to rotate when Control valve is not functioning properly. Check control valve for correct spool and control is in ‘off’ position. leakage. Table 5. Troubleshooting Chart EATON Vane Motors M-2740-S June 2011...
MF214 round type stones with 60 conical ends for inside corners). Replace the rotor if the slots are worn. Replace vanes with a new vane and spring kit if the vane tips are worn. EATON Vane Motors M-2740-S June 2011...
Page 14
(including bushing) Back-up Cover Ring Torque Table Bolt 95 - 150 lb. ft. 25M-20 190 - 210 lb. ft. 35M-20 45M-20 290 - 310 lb. ft. 355 - 375 lb. ft. 50M-20 Figure 10. EATON Vane Motors M-2740-S June 2011...
Tighten the screws Testing If test equipment is available, the motor should be tested at the recommended speeds and pressures shown on the installation drawings (Table 1). EATON Vane Motors M-2740-S June 2011...
Need help?
Do you have a question about the M2-200 Series and is the answer not in the manual?