Serialselect Options - Adaptec RAID 1220SA Installation And User Manual

Sas and sata hostraid controller
Hide thumbs Also See for RAID 1220SA:
Table of Contents

Advertisement

To access SerialSelect:
1
Restart the computer, then press Ctrl+A when prompted to access the ARC utility.
2
If multiple HostRAID controllers are installed, select the HostRAID controller you want to
configure, then press Enter.
3
From the ARC menu, select SerialSelect Utility.
4
To select a menu option, browse with the arrow keys to the option, then press Enter. In
some cases, selecting an option displays another menu. You can return to the previous
menu at any time by pressing Esc.
5
To restore the original SerialSelect default values, press F6 from within the SAS Driver and
Controller Configuration screens.
6
To exit SerialSelect, press Esc until a message prompts you to exit (if you changed any
settings, you are prompted to save the changes before you exit).
7
At the prompt, select Yes to exit, then press any key to restart the computer. Any changes
you made in SerialSelect take effect after the computer restarts.

SerialSelect Options

The following table lists the available and default settings for each SerialSelect option and the
description of each option. The default settings are appropriate for most systems and appear in
bold type in the table. Adaptec recommends that you do not change the settings.
SerialSelect Options
Controller Configuration
Runtime BIOS
BBS Support
RAID Support
POST Banner Display
CTRL-A Message
Available Settings
Description
Enabled
Controls the state of the BIOS at POST time. When
Disabled
Enabled, the
Disabled:Scan bus
the controller to act as a bootable device.
Disabling the BIOS allows another suitable
HostRAID
Device
When BBS support is set to Device base, the
Controller
system's BIOS will list each connected bootable
device to the
individual entry. When BBS support is set to
Controller base, the system's BIOS will only list
HostRAID
the
order. This is useful in a multi-
controller configuration.
Enabled
When there are active arrays in the system, will
Disabled
not allow you to Disable RAID support.
Enabled
When Enabled, the Adaptec banner, version, and
Disabled
copyright is displayed. When Disabled, the
Adaptec banner, version, and copyright is not
displayed.
Enabled
When set to Enabled, the SAS
Disabled
controller BIOS displays the Press <Ctrl> <A> for
ARC Utility message on your screen during system
bootup. If this setting is disabled, you can still
invoke the ARC utility by pressing Ctrl+A after the
SAS HostRAID controller BIOS banner appears.
Appendix C: Using the ARC Utility
HostRAID
controller BIOS allows
controller to act as the boot device.
HostRAID
controller as an
controller in the system boot
HostRAID
HostRAID
74

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents