Verifying and Fixing a Logical Drive

Note:
To verify a logical drive without fixing it, see
While ICP Storage Manager verifies and fixes a logical drive, you can't complete any other tasks
on the controller. Because the verification can take a long time to complete, you may want to
schedule it as a task to be completed overnight or on a weekend.
To verify and fix a logical drive:
1
Ensure that no activity is taking place on the controller associated with the logical drive
you want to verify and fix.
2
In the Enterprise View, click the controller.
3
In the Logical Devices View, click the logical drive.
4
In the menu bar, select Actions, then click Verify with fix.
5
To begin the verification immediately, click Yes.
To schedule the verification, click Schedule, then set the date and time. You can also choose
to set the verification as a recurring task. (For more information on scheduling tasks, see
page
77.)
Note:
Don't power off the system while the verification is in progress. If you do, the verification
will stop.
While the verification is in progress, the logical drive is shown as an animated icon
(as shown at right) to indicate that the task is in progress.
When the verification is complete, an event notice is generated in the local system's event
log (and broadcast to other systems, if you have event notification set up—see
Users by Event Log Message About Status and Activity on page
You can now continue working on the controller.

Verifying a Logical Drive (Without Fix)

Note:
To verify and fix a logical drive, see
While ICP Storage Manager verifies a logical drive, you can't complete any other tasks on the
controller associated with that logical drive. Because verification takes a long time to complete,
you may want to schedule it as a task to be completed overnight or on a weekend.
To verify a logical drive:
1
Ensure that no activity is taking place on the controller associated with the logical drive
you want to verify and fix.
2
In the Enterprise View, click the controller.
3
In the Logical Devices View, click the logical drive.
4
In the menu bar, select Actions, then click Verify.
Chapter 6: Modifying Your Direct Attached Storage
page
69.
page
69.
69
Notifying
98).