Low Credit Threshold
Maximum Demand Configurable Time
Period
Maximum Meter Balance Threshold
Meter Point Administration Numbers
(MPAN)
Medium High Power Threshold
Non-Disablement Calendar
Payment Mode
Public Key Security Credentials Store
Randomised Offset Limit
RMS Extreme Over Voltage Measurement
Period
RMS Extreme Over Voltage Threshold
RMS Extreme Under Voltage
Measurement Period
RMS Extreme Under Voltage Threshold
RMS Voltage Sag Measurement Period
RMS Voltage Swell Measurement Period
Standing Charge
Supplier Message
Supply Tamper State
Suspend Debt Disabled
Suspend Debt Emergency
Tariff Block Price Matrix
Tariff Threshold Matrix
Tariff TOU Price Matrix
© Honeywell - M450 001 1D - 23.05.2019
Operating & Maintenance Instructions
Threshold in Currency Units below which a low credit Alert is signalled.
Time period of up to 24 hours comprising a number of half-hour periods
(commencing at the start of minutes 00 and 30 in each hour) during which
recording to the Maximum Demand (Configurable Time) Active Power Import
Value (0) is active.
Threshold in Currency Units above which an Add Credit Command is rejected.
The reference numbers identifying an electricity metering point for Import and
Export.
A value in kW defining the threshold between an indicative medium and high
Active Power Import Level
A Switching Table comprising a set of rules specifying periods during which the
Supply will not be Disabled
The current mode of operation, being Prepayment Mode or Credit Mode.
Store for Security Credentials relating to Public Keys.
A value in seconds in the range 0 to 1799.
Duration in seconds used to measure an extreme over voltage condition.
RMS voltage above which an extreme over voltage condition is reported.
RMS Extreme Under Voltage Measurement Period
RMS voltage below which an extreme under voltage condition is reported.
Duration in seconds used to measure a voltage sag condition.
The RMS voltage below which a sag condition is reported
A charge to be levied in Currency Units per unit time when operating in Credit
Mode and Prepayment Mode.
Message issued to, and held on, AS302P for provision to the Consumer
Setting to control the state of the Supply in the case of Unauthorised Physical
Access being detected, being Locked or unchanged.
Setting controlling whether standing charge and debt should be collected when
AS302P is operating in Prepayment Mode and Supply is Disabled
A setting controlling whether standing charge and debt should be deducted from
the Emergency Credit Balance
Set of rules for allocating half-hourly Consumption to a Tariff Register
Matrix capable of holding thresholds in kWh for controlling Block Tariffs
Matrix containing prices for Time-of-use Pricing.
79