Honeywell AS302P Operating Instructions Manual page 77

Single phase smart meter
Table of Contents

Advertisement

__________________________________________________________________________
Event Log (Contd)
Event / Alert Code Meaning
Error Watchdog
Meter Cover Closed
Request Tunnel Command Rejected
Strong Magnetic Field Removed
Supply Connect Failure (Valve or Load Switch)
Supply Disabled Then Locked - Supply Tamper
State Cause
Supply Disconnect Failure (Valve or Load Switch)
Terminal Cover Closed
UTRN Manual Entry Suspended
UTRN rejected as locked out
Power Event Log
Event / Alert Code Meaning
Average RMS Voltage above Average RMS
Over Voltage Threshold (current value above
threshold; previous value below threshold)
Average RMS Voltage below Average RMS
Under Voltage Threshold (current value below
threshold; previous value above threshold)
RMS Voltage above Extreme Over Voltage
Threshold (voltage rises above for longer than
the configurable period)
RMS Voltage above Voltage Swell Threshold
(voltage rises above for longer than the
configurable period)
RMS Voltage below Extreme Under Voltage
Threshold (voltage falls below for longer than the
configurable period)
RMS Voltage below Voltage Sag Threshold
(voltage falls below for longer than the
configurable period)
Supply Outage Restored
Supply Outage Restored - Outage >= 3 minutes
Supply Outage Restored on Phase 1
Supply interrupted
Average RMS Voltage below Average RMS
Over Voltage Threshold (current value below
threshold; previous value above threshold)
Average RMS Voltage above Average RMS
Under Voltage Threshold (current value above
threshold; previous value below threshold)
RMS Voltage above Extreme Over Voltage
Threshold (voltage returns below for longer than
the configurable period)
RMS Voltage above Voltage Swell Threshold
(voltage returns below for longer than the
configurable period)
RMS Voltage below Extreme Under Voltage
Threshold (voltage returns above for longer than
the configurable period)
RMS Voltage below Voltage Sag Threshold
(voltage returns above for longer than the
configurable period)
© Honeywell - M450 001 1D - 23.05.2019
Operating & Maintenance Instructions
Event /
Mandated /
Alert Code
Non-mandated
0x81B3
Non-mandated
0x81B9
Non-mandated
0x81BA
Non-mandated
0x81BC
Non-mandated
0x81BD
Non-mandated
0x81BE
Non-mandated
0x81C0
Non-mandated
0x81C1
Non-mandated
0x81C4
Non-mandated
0x81C5
Non-mandated
Event / Alert
Mandated /
Code
Non-mandated
0x8002
Mandated
0x8006
Mandated
0x8020
Mandated
0x8024
Mandated
0x8028
Mandated
0x802C
Mandated
0x8F35
Mandated
0x8F36
Mandated
0x8F37
Mandated
0x8157
Mandated
0x8085
Mandated
0x8089
Mandated
0x808D
Mandated
0x8091
Mandated
0x8095
Mandated
0x8099
Mandated
Alert
Alert
WAN
HAN
(Alert Type)
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
Y
Y (1)
N
Alert
Alert
WAN
HAN
(Alert Type)
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
N
Y (2)
N
Y (2)
N
Y (2)
N
N
N
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
N
Y (1)
N