Plane of vibration to be along three mutually perpendicular axes.
B.1.7
SHOCK
The subject power supplies will withstand the following imposed
conditions without experiencing non-recoverable failure or deviation
from specified output characteristics.
Storage
–40G, 11 mSec. half-sine wave pulse in both directions on
three mutually perpendicular axes.
Operating -10G, 11mSec. half-sine wave pulse in both directions on
three mutually Perpendicular axes.
B.1.8
SAFETY
NEMKO EN 60950
TUV EN60950 OR VDE EN60950
CSA-C22.2 NO. 60950
IEC 60950
UL 60950
CE:
EN 55022:1998+A1:2000,Class B
EN 61000-3-2:2000
EN:61000-3-3:1995+A1:2001
CISPR22:1997+A1:2000,Class B
AS/NZS CISPR 22:2002, Class B
B.1.9
MTBF
The power supply have a minimum predicted MTBF(MIL-HDBK-217)
of 100,000 hours of continuous operation at 25℃, maximum-out load,
and nominal AC input voltage.