D-100 FLOW DISPLAY with NETWORK INTERFACE
Installation and Operation Guide
With
BACnet Network Interface Installation Guide
1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699
www.onicon.com • sales@onicon.com
0634-7 / 18340
08-12

Advertisement

Table of Contents
loading

Summary of Contents for Onicon D-100

  • Page 1 D-100 FLOW DISPLAY with NETWORK INTERFACE Installation and Operation Guide With BACnet Network Interface Installation Guide 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 www.onicon.com • sales@onicon.com 0634-7 / 18340 08-12...
  • Page 2 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7 Page 2...
  • Page 3: Table Of Contents

    5.1.2 Flow Test Signals ................27 5.1.3 Ai3 & Ai4 Test Signals ..............27 Troubleshooting ..................28 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08-12 - 0634-7 Page 3...
  • Page 4 D-100 ANALOG OUTPUT BOARD D-100 ANALOG OUTPUT BOARD With 4 Analog Outputs CONDITIONS OF SALE 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7 Page 4...
  • Page 5: Introduction

    Interface Module. TYPICAL D-100 NETWORK INTERFACE MODULE The D-100 is a totalizing display module that provides a local indication of liquid, gas or steam flow rate and total data. It can also be configured with an optional network interface to communicate data to the building control network.
  • Page 6 Two auxiliary analog rate inputs: 4-20 mA One auxiliary totalizer input: pulse or contact closure 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7 Page 6...
  • Page 7: Additional Hardware Required

    The ONICON D-100 is delivered fully programmed and ready to use with a specific flow meter. The serial number of the flow meter and any other sensor used with this D-100 will be found on a label located inside the enclosure. Do not attempt to use the D-100 with any other flow meter or sensor.
  • Page 8: Installation

    Find an easily accessible location where wire connections can be made and meter readings can be taken from floor level. Mount the D-100 on a vibration free surface. Avoid locations such as the plenum of a fan coil, heat exchanger or any housing that may contain electric motors or other strong sources of electrical interference.
  • Page 9: Mechanical Installation

    Do not drill additional holes in this enclosure. Doing so may damage the electronic circuitry contained within and will void all warranties. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08-12 - 0634-7...
  • Page 10: Electrical Installation

    Make connections on the mother board, located inside the enclosure, at terminal strips T3 and T4. Do not exceed 4.5 in-lb (0.5 Nm) of torque when tightening. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7...
  • Page 11: Onicon Turbine Flow Meters

    Shield connections are required for proper operation. Failure to use shielded cable or to properly terminate shield connections may result in erratic operation. Shields should be terminated in the D-100 at the terminals provided. The shield connection at the flow meter should be left unterminated.
  • Page 12: Onicon F-3500 Flow Meters

    Shield and earth connections are required for proper operation. Failure to use shielded cable or to connect earth to both the flow meter and D-100 may result in erratic operation. Shields should be terminated at the D-100 shield terminals and left unterminated at the flow meter.
  • Page 13: Onicon F-3100 And F-3200 Flow Meters

    Shield and earth connections are required for proper operation. Failure to use shielded cable or to connect earth to both the flow meter and D-100 may result in erratic operation. Shields should be terminated at the D-100 shield terminals and left unterminated at the flow meter.
  • Page 14: Onicon F-2500 Flow Meters

    Shield and earth connections are required for proper operation. Failure to use shielded cable or to connect earth to both the flow meter and D-100 may result in erratic operation. Shields should be terminated at the D-100 shield terminals and left unterminated at the flow meter.
  • Page 15: Onicon F-5100 Series Flow Meters

    Shield and earth connections are required for proper operation. Failure to use shielded cable or to connect earth to both the flow meter and D-100 may result in erratic operation. Shields should be terminated at the D-100 shield terminals and left unterminated at the flow meter.
  • Page 16: Onicon F-5200 Series Flow Meters

    D-100 at the terminals provided. The shield connection at the flow meter should be left unterminated. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7...
  • Page 17: Average Frequency (Pulse) Flow Input

    This register can be zeroed on demand via the network. Contact ONICON for more information. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08-12 - 0634-7...
  • Page 18: Totalizer Outputs And Mode Status

    Analog output signal connections are made at T1 terminals 7 through 14. Do not exceed 4.5 in-lb (0.5 Nm) of torque, when tightening the terminals. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7...
  • Page 19: Input Power

    Earth Connection 120V NEUTRAL 1/4 AMP LED1 120VAC NEUTRAL 20075-50 REV. A Input Power Connection 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08-12 - 0634-7 Page 19...
  • Page 20 VAR1 Earth Connection 1/4 AMP NEUTRAL LED1 NEUTRAL 20075-50 REV. A Input Power Connection 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7 Page 20...
  • Page 21: D-100 Start-Up And Commissioning

    GPM, GPH, MGD, l/s, l/min, l/hr, M /hr, Ft /m, lb/hr, kg/hr, Flow Rate SCFH, SCFM, NCMH Serial Number None 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08-12 - 0634-7 Page 21...
  • Page 22: Units And Multipliers

    If any unit or multiplier values are changed at the D-100, the analog output value(s) will also be changed. If you are unsure of the ramifications of any changes you are contemplating, please contact ONICON for assistance.
  • Page 23: Commissioning

    Shane Hamilton ONICON Incorporated certifies that the flow and temperature sensors provided with this Btu meter have been individually calibrated based on the application specific data provided above; using standards directly traceable to the U.S. National Institute of Standards and Technology (N.I.S.T.).
  • Page 24 Calculated: Calculated: Calculated: Record displayed values D-100: D-100: D-100: System: System: System: 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7 Page 24...
  • Page 25: Diagnostics

    Ai4 will produce an output equal to 37.5% of their programmed full scale output. This test confirms the operation of the D-100 processor board input circuitry for Ai3 and Ai4. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08-12 - 0634-7...
  • Page 26: Troubleshooting

    • If applicable, verify the Baud rate. • Check the polarity of the network connections. For technical assistance, contact ONICON Incorporated at (727) 447-6140. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7 Page 26...
  • Page 27 D-100 ANALOG OUTPUT BOARD D-100 ANALOG OUTPUT BOARD With 4 Analog Outputs CONDITIONS OF SALE 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08-12 - 0634-7 Page 27...
  • Page 28 *Standard: 24 VAC 1. COMMUNICATIONS BOARD Optional: 120 or 230 VAC 2. ANALOG OUTPUT BOARD 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7 Page...
  • Page 29 D-100 PROCESSOR BOARD RESET TEMP TEST PROG MODE ENABLE DEVICE ADDRESS PROGRAM ENABLE SERIAL COMM 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7 Page...
  • Page 30 1 AMP 1/4 AMP 1/8 AMP 250 VOLT 250 VOLT 250 VOLT SLO-BLO SLO-BLO SLO-BLO 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7 Page...
  • Page 31 D-100 ANALOG OUTPUT BOARD FLOW DELTA T BTU RATE LO TEMP HI TEMP 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7 Page...
  • Page 32 D-100 ANALOG OUTPUT BOARD with 4 analog outputs 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Flow Display Manual 08/12 - 0634-7 Page...
  • Page 33 2. DELIVERY AND TITLE: All product shipments are F.O.B. shipping point and title passes to the Buyer at the time ONICON delivers the merchandise to the carrier. Risk of loss or damage to the product passes to the Buyer at the time ONICON delivers the product to the carrier. The Buyer immediately upon receipt should inspect all shipments, and should there be any evidence of damage or loss in transit, Buyer must file claims or tracers upon carrier.
  • Page 34 BACnet D-100 FLOW DISPLAY BACnet Network Interface Installation Guide 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 www.onicon.com • sales@onicon.com 0635-2 04-12...
  • Page 35 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 2...
  • Page 36 D-100 BaCnet Ms/TP BOaRD D-100 BaCnet IP BOaRD D-100 BaCnet/IP auxiliary Output Board 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 3...
  • Page 37 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 4...
  • Page 38: Introduction

    ONICON D-100 BaCnet serial interface. TYPICAL D-100 FLOW DISPLAY The D-100 is a totalizing display module that provides a local indication of liquid, gas or steam flow rate and total data. It can also be provided with an optional BaCnet Ms/TP or BaCnet/IP serial interface to communicate data to the building control network.
  • Page 39: Network Signal Connections

    Incoming and outgoing Rs485 cable shield wires should be connected together, but must not be connected to the display. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2...
  • Page 40: Bacnet/Ip

    ONICON assumes no responsibility for damage caused to the external equipment as a result of an improper installation. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2...
  • Page 41: Optional Network Interface With Isolated Auxiliary Pulse Input

    NOTe: BaCnet Ms/TP shown above. see appendix a-4 for BaCnet/IP auxiliary output board. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2...
  • Page 42 (see fig. 3). set the selector switch, s1 to sRC. The switch must be rated for at least 20ma at 20VDC. fig. 3 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 9...
  • Page 43 In either case, the switch must be rated for at least 20ma at 20 VDC. fig. 4 fig. 5 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 10...
  • Page 44: Bacnet Ms/Tp Baud Rate, Biasing And Termination

    The standard Baud rate settings are 9600, 19200, 38400 and 76800 Baud. If the Baud rate setting was not provided to ONICON, the D-100 will be configured to “auto” detect the Baud rate of the network. In this configuration, the display should detect and automatically adjust to the proper rate when it is connected to the network.
  • Page 45: Biasing And Termination

    001 – 254. The device instance number can be any number from 0 – 4,194,303. Both addresses are entered via the D-100 user interface on the front panel of the display. The procedure for entering or changing either the MaC address or the device instance number is outlined in the table on the next page.
  • Page 46 The new addresses are saved and the PROGRaM pushbutton. display will revert to the RUN mode. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 13...
  • Page 47: Changing The Ip Address

    Remote User Interface main menu (shown on the next page) select option “I”, Change IP address. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2...
  • Page 48 IP address as shown below and press enter. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2...
  • Page 49 D-100 for the change to take effect. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2...
  • Page 50: Changing The Gateway Address

    Remote User Interface main menu (shown below) select option “I”, Change IP address. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2...
  • Page 51 IP address settings menu (shown below) select option 3. enter the new gateway address as shown below and press enter. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2...
  • Page 52 D-100 for the change to take effect. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2...
  • Page 53: Bacnet Pics And Objects

    SECTION 2.0: BACnet PICS AND OBJECTS PIC STATEMENTS 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 20...
  • Page 54 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 21...
  • Page 55: Bac Objects

    Binary Value 15 Zero auxiliary Input Not applicable Total 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 22...
  • Page 56: Network Troubleshooting Tips

    • background noise on the cable. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 23...
  • Page 57 (see section 1.6.2 of this • manual for details.) 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 24...
  • Page 58 • Rs485 connector on the D-100. 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page 25...
  • Page 59 Temp Test Prog Mode Enable Device Address Program Enable Serial Comm 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page A-1...
  • Page 60 D-100 BACnet MS/TP BOARD Baud Rate Switches Transmit Receive Termination Resistor 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page A-2...
  • Page 61 Green - LED Yellow - LED Network Network Activity Link 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page A-3...
  • Page 62 RJ45 Connector (T1) Pulse Type Selector Switch (S1) Input Impedance Jumper (J1) 1500 North Belcher Road, Clearwater, FL 33765 • Tel (727) 447-6140 • Fax (727) 442-5699 • sales@onicon.com D-100 Display Module BACnet Installation and Operation Guide 04/12 - 0635-2 Page A-4...

This manual is also suitable for:

Jci metasys n2

Table of Contents