Upload (From The Device To The Hotkey) - Emerson XM670 Installation And Operation Manual

Controllers for multiplexed cabinets
Table of Contents

Advertisement

13.2. Upload (From the
Device to the Hotkey)
1. When the XM controller is ON, insert the Hot
Key into the 5-pin connector labeled HOT-KEY.
2. Press and release the up arrow button.
3. The upload will begin, and UPL will blink on the
display. End will display at the end of the data
transfer phase if a successful upload has
occurred. Err will display if there is an error or
failure in programming.
• End = correct programming.
• Err = failed programming. In this case, press the
SET key if you want to restart the programming
again or remove the unprogrammed Hot Key.
4. Remove the Hot Key.
Note: The upload procedure will overwrite everything
previously uploaded from the last Hot Key upload.

Upload (From the Device to the Hotkey)