Page 2
CrustBuster/Speed King,Inc. an opportunity to inspect. Unless otherwise expressly agreed to by CrustBuster/Speed King,Inc., the consumer shall bear the expense of installation. CrustBuster/Speed King, Inc. will not be liable for consequential damages where the loss is commercial, including but not limited to loss of profit, delays or expenses.
Page 3
Operator Qualifications Operation of this BeltVeyor shall be limited to competent and experienced persons. In addition, anyone who will operate or work around BeltVeyor must use good common sense. In order to be qualified, he or she must also know and meet all other requirements, such as: Some regulations specify that no one under the age of 16 may operate power machinery.
Page 4
BE ALERT! Your Safety is involved. General Safety Statement WATCH FOR THIS SYMBOL. IT POINTS OUT IMPORTANT ) ) ) ) )) SAFETY PRECAUTIONS. IT MEANS "ATTENTION BECOME ALERT!" YOUR SAFETY IS INVOLVED. It is your responsibility as an owner, operator, or supervisor to know and instruct everyone using this BeltVeyor at the time of initial assignment and at least annually thereafter, of the proper operation, precautions, and work hazards which exist in the operation of this BeltVeyor in accordance with OSHA Regulations.
Page 5
8. Make sure all safety devices, shields, and guards are in place and are functional before beginning the operation. 9. Shut off power to adjust, service, or clean the BeltVeyor. 10. Keep hands, feet, and clothing away from moving parts. It is a good idea to remove all jewelry before starting the operation.
Page 6
Pre-Operation Check List Check all bearings for proper lubrication. Check the tube for foreign material. Check all belts for proper tension. Start unit and check conveyor belt alignment while unit is empty. BELT CARE ……… It is suggested that the unit be run every two to three days or more often if possible. This tends to keep the conveyor belt alive and stops any forming of the belt to the curvature of the tube while the unit is not in use.
Page 7
After extended use, the conveyor belt may stretch to the point that there is not sufficient take-up in the drive assembly to tighten it. Obtain additional take-up by cutting a 6" to 8" section from the belt. A new splice lacing may be ordered from your CrustBuster/Speed King distributor or from the factory.
Page 8
Operation Prior to the start-up, check to see that belt is free from any objects that would bind or tear. On starting for the first time, with no load on belt, apply power for a few seconds only to see that the conveyor belt travels in the proper direction, and is well centered in the tube and on the return.
Page 9
Troubleshooting If the BeltVeyor equipment malfunctions, the source of faulty operation may frequently be found by observing the nature of the fault and applying some simple checks and remedies to correct the malfunction. The following troubleshooting table is provided for this purpose. BELTVEYOR TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSES...
Page 11
10" BVTC HORSEPOWER Electric Unit Hydraulic Unit with Belt without Belt *See note below Undercar Undercar 7½ 8" Drive 7½ Requirements: 7½ 15 gallons per minute 7½ at 1650 psi. 7½ 10" Drive Requirements: 20 gallons per minute at 2000 psi * In order to operate a hydraulic drive BeltVeyor and a hydraulic Slip-Pit or Field Loader conveyor off of the same tractor, the tractor will need to have a Closed Center Hydraulic System...
Page 15
10" BVTC Band Locations 35' PTO/Gas/Hyd/Electric 35' PTO/Gas/Hyd 35' Electric Slip-Pit™ Accelerator Not Slip-Pit™ Accelerator Not Available with 35' PTO Available with 35' Electric...
Page 16
10" BVTC Band Locations 40' PTO/Gas/Hyd/Electric 40' PTO/Gas/Hyd 40' Electric Slip-Pit™ Accelerator Not Available with 40' Electric...
Need help?
Do you have a question about the Speed King 10" BeltVeyor and is the answer not in the manual?
Questions and answers