How to Wire Your Ceiling Fan & Install the Control
General
This control is designed to operate only one ceiling fan
6. Before disconnecting power, ensure that the fan is
set at the highest speed.
NOTE: Electric connections should be in
accordance with the National Electrical Codes and
all Local Codes. Before starting, disconnect power
to the circuit at the fuse box or circuit breaker
panel.
7. Remove the faceplate and screws from the existing
wall switch. Pull switch out from wall outlet box.
8. Disconnect wire from existing fan wall switch
(Figure 12).
9. Slide the Fan Control to the OFF position (0).
10. Connect one BLACK wire from the Fan Control to
the fan/motor lead with a wire connector (provided).
(Figure 13.)
11. Connect the other BLACK wire from the Fan
Control to the 120VAC hot wire with a wire
connector (provided with control).
NOTE: Use wire connectors (supplied) to secure
electrical connections.
12. Attach the Fan Control to the wall outlet box with
two 6-32 x 3/4" screws (provided with control).
13. Position the faceplate (provided with control) onto
the speed control. Using the two 6-32 x 1/4"
screws, screw the faceplate and speed control to
the wall outlet box (Figure 14).
14. Restore power at the main fuse box or circuit
breaker panel.
Figure 12
TO NEUTRAL
Figure 13
SW46 FAN CONTROL
6-32 x 1/4" SCREW (2)
Figure 14
Please contact 1-800-654-3545 for further assistance
9
(con't.)
WALL
OUTLET
SWITCH
BOX
FACEPLATE
TO FAN MOTOR LOAD
BLACK
4
BLACK
3
2
1
0
OUTLET BOX
4
3
2
1
0
6-32 x 3/4"
SCREW (2)
FACEPLATE
emersonfans.com
U.L. Model No.: CF765-1
TO
120VAC
SOURCE
HOT