(4) Protection against water and dust
CAUTION:
① Install the wiring at a (upper) position where the wiring is
not likely to be damaged by water, dust, mud or snow pile,
freezing or flying stones, or where it is not buried under
dust or sand.
② Always use a grommet at a metal plate through hole to
protect the wiring against water entry or damage.
③ Mount a cover or a protector to prevent water entry along
the wiring.
·
A water-proof boot should be installed facing down.
④ A connector, if used at a position exposed to water, should always be of water-proof type.
⑤ To prevent water from running along wires, always make
connections that the connector/terminal of electrical
equipment is higher than the wire.
⑥ After have modification on current vehicle, should maintain or keep current part condition as the same
condition (e.g. tape lap method, COT shape, etc.) to prevent OEM vehicle system problem occurrence.
【3】-12. Electrical wirings