Delta CP.0.DPS Series Operation Manual page 19

230/400 volt
Table of Contents

Advertisement

Load drifts
excessively when
winch is stopped
Winch operates
intermittently
Abnormal noise from
wirerope/drum.
Emergency procedure: In the event of a blocked steel wire or any other
malfunction of
DANGER
without attempting any further actions. Immediately set up a safety perimeter
around the winch and the load to prevent access by any unauthorized persons. Call
in the necessary personnel to remove the load and intervene on the winch.
Overload.
Motor brake not holding
Loose connections
Lake of lubrication, worn
wire rope/drum
electric pulling winch, immediately stop the maneuverer
Reduce loading to rated load, as shown on
nameplate.
With No Load, check winch for drift. If drifting is
excessive, inspect motor brake and adjust it.
Check all wiring for loose connections
Check all wiring for loose connections