(319) WARNING: Unable to obtain negotiation from network:
system error <system_error>: <system_message>
CAUSE: There was no Telnet negotiation to receive from the network due to the
system error given.
ACTION: Look up what the select(2) man page states about the system error
given and make the correction as appropriate.
(320) WARNING: No negotiation to obtain from network within time interval allowed
CAUSE: There was no data and thus no Telnet negotiation to receive from
the network during the time to wait for such negotiations (most likely
because of the load on the terminal server, network, or system).
ACTION: Determine if the terminal server and device are operational and make
them operational if they are not.
(321) WARNING: Unable to read negotiation from network:
system error <system_error>: <system_message>
CAUSE: There was no Telnet negotiation to read from the network due to the
system error given.
ACTION: Look up what the read(2) man page states about the system error
given and make the correction as appropriate.
(322) WARNING: No negotiation to obtain from network
CAUSE: Unexpected data was received from a place other than the network
before there was a Telnet negotiation to receive from the network.
ACTION: No action is necessary.
(323) WARNING: No status reply from device
CAUSE: No status reply was received in the data from the device on the remote
terminal server.
ACTION: No action is necessary.