Advertisement

CCV InSync
CCV InSync C
System Manual

Advertisement

Table of Contents
loading

Summary of Contents for CCV InSync

  • Page 1 CCV InSync CCV InSync C System Manual...
  • Page 2 CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 2...
  • Page 3: Table Of Contents

    General technical information 4.6.1. Vending machine and/or cash register interfaces 4.6.2. Display 4.6.3. Receipt printer 4.6.4. IP/IK protection class 4.6.5. Status LEDs 4.6.6. Card slot for store card or SAM 4.6.7. Communication CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 3...
  • Page 4 USB OTG 5.4.7. USB host 5.4.8. Digital I/O 5.4.9. Internal circuit diagram and information on Digital I/O 5.4.10. Service 5.4.11. Modem (optional) 5.5. Specifications 5.6. Cash register protocols 5.6.1. ZVT specification CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 4...
  • Page 5 5.6.2. O.P.I. 5.6.3. Executive (Protocol A) 5.6.4. 6. Failure statistics, characteristic figures 7. EU – Declaration of Conformity 8. EMC certificates CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 5...
  • Page 6: Purpose

    1. Purpose These specifications shall facilitate the integration of the self-service terminal CCV InSync into a vending machine 2. Scope of application Customers, integrators, network operators, (CCV- EW, SA, PM) 3. Terms and abbreviations Bitmap Deutsche Kreditwirtschaft (German Banking Industry Committee) (previously ZKA;...
  • Page 7: General

    Never submerge the terminal in water, throw into fire or expose to high humidity. The device should be cleaned with a soft damp cloth. Do not use chemical cleaners.  Repairs may only be performed by authorized agents of CCV.  Do not expose the device to temperatures outside the approved limits.
  • Page 8: Important Information For Use

    (ESD-electrical grounding).  Check the integrity of the CCV InSync. Check if the CCV InSync shows damage and manipulation and the seal is unbroken. If you detect damage, tampering or a broken seal do not operate the CCV InSync.
  • Page 9: System Description

    It is resistant to vandalism, weather-resistant and can be used in a large temperature range. The CCV InSync Terminal is thus suitable for both indoor and outdoor use. It requires the same installation space and the same fixing points as the CCV COR series.
  • Page 10: User Guidance

    4.5. User guidance Users of the CCV InSync find it easy to use the terminal – thanks to the intuitive menu navigation and the texts on the big graphic display. The CCV InSync can be managed conveniently via the TS3, available free of charge.
  • Page 11: General Technical Information

    The receipt for payment is output on the printer integrated in the vending machine. It is controlled via the vending machine control. The vending machine receives the data as completed receipt from the CCV InSync or as data message with all relevant data to create an individual receipt layout (sequence depend on the cash register protocol).
  • Page 12: Status Leds

    4.6.5. Status LEDs On the back of the CCV InSync, there are two LEDs “PWR” (Power) and “SYS” (System) which have the following meaning: Status SYS (red, controllable) (green) Booting permanently lit permanently lit 2x flashing slowly, Terminal ready, waits for login...
  • Page 13: Protocols

     POSeidon  CCV Pay 4.6.10. Software The CCV InSync Terminal uses a Linux operating system with our company’s SECpos EVO software. 4.7. Service 4.7.1. Integration into cash register or vending machine systems As support for the adaptation or integration to or into the cash register, a development toolkit with the following...
  • Page 14: Software Update

    CCV. Please observe that the terminal must not be disconnected from the power supply while updating the software. Otherwise, the update might be activated only in part and the device must be sent to CCV. 4.7.4. Maintenance and troubleshooting With the terminal configuration server TKS/TMS2.0, it is not only possible to update the software but also to...
  • Page 15: Terminal Security State

    Terminal Security State The 4 digit hexa-decimal TSS is displayed via the TS3 in the display of the CCV InSync during booting. The first two digits of the terminal security state identify the concerned component; the last two digits represent the state of this component.
  • Page 16: Specifications / Dimensions

    Specifications / dimensions 5.1. Figures and dimensions front view rear view side view CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 16...
  • Page 17: Installation Space

    0.8 Nm +/- 0.2 Nm  The nuts must be secured with locking varnish.  The terminals must be earthed via a fixing screw (cross-section of the earth connection min. 2.5 mm CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 17...
  • Page 18: Interfaces

    RXD (In) RTS (In) CTS (Out) MDB_WAKE Power GND 5.4.2. RJ45 8-pin, shielded Signal (switched; 7VDC to 45VDC) RXD (In) TXD (Out) MDB_WAKE CTS (Out) RTS (In) Signal GDN Power GND CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 18...
  • Page 19: Mdb

    Signal MDB PWR IN MDB PWR GND MDB-WakeUp MDB-Master Receive MDB-Master Transmit MDB-Com Common 5.4.4. Voltage supply for the CCV InSync must not be fed via LAN. RJ45 8-pin, CAT5 Signal 5.4.5. PWR/Executive (voltage supply) Signal EXE-Master Rx EXE-Master Rx...
  • Page 20: Usb Otg

    - Type B: not connected (OTG device works as periphery) black Earth To switch the OTG mode of the CCV InSync to host, a specific OTG cable is required. Use OTG port as device: OTG port without cable Device cable, not connected to PC...
  • Page 21: Digital I/O

    DigIn 1 DigOut 5.4.9. Internal circuit diagram and information on Digital I/O A component „HITFET-BTS3800SL“ was used for the digital I/O ports. Please take the according information from the datasheet below. CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 21...
  • Page 22: Service

    A 2/4G modem for the serial port will be optionally available. The settings for mobile standards can be viewed via the TS3 and changed, if required. Please ask your contact about availability of the modems. CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 22...
  • Page 23 Country Code (MCC) corresponds to the national prefix. The national prefix can be used to differentiate between national and international locations. When international roaming is activated, the national prefix is not evaluated. CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 23...
  • Page 24: Specifications

    107 kBaud at 10 MHz, compatible to ISO 7816 Voltage supply Terminal: 9-45 V (protection against voltage reversal) Power consumption: ~200mA at 12 V Standby: Power consumption: ~6 mA at 12 V CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 24...
  • Page 25 50% of this period. The ambient conditions for storage and operation as described in this system manual must be observed for this purpose. Only the manufacturer CCV Deutschland GmbH may replace the battery.
  • Page 26: Cash Register Protocols

    ZVT specification www.zvt-kassenschnittstelle.de The specification provided for download on our website are used as the basis for an implementation of the ZVT cash register protocol. CCV does not guarantee the completeness of the ZVT specifications. 5.6.2. O.P.I. As a basis for the implementation of the O.P.I. interface, the specification „PA77S001 – CCV O.P.I. Interface“ is used.
  • Page 27 EU – Declaration of Conformity CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 27...
  • Page 28 EMC certificates CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 28...
  • Page 29 CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 29...
  • Page 30 CCV InSync System Manual Rev.03 04/2019 PA91P003 | Page 30...

This manual is also suitable for:

Insync c

Table of Contents