Chapter 7. Applications
Table 7-2. Multiport Application Configuration Example (Continued)
DTE 4 (V.35)
System
Management
FRACTIONAL T3 CARRIER APPLICATION
When network providers want to provide service at rates less than
full T3, T3SU 300 units can be used in pairs for deploying sub-T3
rate services.
In this application example (shown in Figure 7-3), a carrier
provides fractional T3 access at 8 Mbps for internet connectivity.
The data connection can be either V.35 or HSSI at either location.
This network uses a HSSI port at the carrier's internet POP (point
of presence) and a high-speed V.35 connection at the customer's
router. The carrier manages both the local and remote T3SU 300s
via SNMP. Table 7-3 gives an example configuration for this
application.
While in DTE Loopback, data from the host is transmitted into the net-
work.
7-4
Local T3SU 300
Port State - Enabled
Nx75k blocks - 20
Local IP Address - 10.4.10.2
Subnet Mask - 255.255.255.0
Gateway IP Address - 10.4.10.1
IP Security - Disabled
Trap IP Address - 10.4.10.10
Management Port - LAN
T3SU 300 User Manual
Remote T3SU 300
Port State - Enabled
Nx75k blocks - 20
Nothing required. Remote unit can
be managed using the local
T3SU 300.
61200217L1-1