iNSTAllATiON
Electrical connection
11.2 Safety extra low voltage
XD04
Terminal, safety extra low voltage
T(MK)
Mixer circuit temperature sensor for HSBC 3-HKM
(optional)
T(KUE)
Temperature sensor for area cooling (optional)
T(WW)
DHW temperature sensor
T(Puffer)
Temperature sensor, buffer cylinder
PWM
Control by WPM
Control by WPM via PWM signal
f Observe the information in the operating and installation in-
f
structions of the WPM heat pump manager.
www.stiebel-eltron.com
11.3 Sensor installation
11.3.1 Temperature sensor for cooling (accessory), if required
Cooling requires the fitting of a temperature sensor, available as
an accessory.
f Remove the front casing (see chapter "Preparations / Trans-
f
port and handling / Removing/fitting the front casing").
f Insert the temperature sensor into the sensor well "Sensor
f
heat pump cooling, optional".
f Lay the sensor lead in the guide groove provided for this pur-
f
pose in the insulation segment.
f Connect the temperature sensor to T(KUE) of terminal XD04
f
of the appliance.
HSBC 300 cool (AU) |
19