Safety Extra Low Voltage; Sensor Installation - STIEBEL ELTRON HSBC 300 cool Operation And Installation

Integral cylinder
Table of Contents

Advertisement

iNSTAllATiON
Electrical connection

11.2 Safety extra low voltage

XD04
Terminal, safety extra low voltage
T(MK)
Mixer circuit temperature sensor for HSBC 3-HKM
(optional)
T(KUE)
Temperature sensor for area cooling (optional)
T(WW)
DHW temperature sensor
T(Puffer)
Temperature sensor, buffer cylinder
PWM
Control by WPM
Control by WPM via PWM signal
f Observe the information in the operating and installation in-
f
structions of the WPM heat pump manager.
www.stiebel-eltron.com

11.3 Sensor installation

11.3.1 Temperature sensor for cooling (accessory), if required
Cooling requires the fitting of a temperature sensor, available as
an accessory.
f Remove the front casing (see chapter "Preparations / Trans-
f
port and handling / Removing/fitting the front casing").
f Insert the temperature sensor into the sensor well "Sensor
f
heat pump cooling, optional".
f Lay the sensor lead in the guide groove provided for this pur-
f
pose in the insulation segment.
f Connect the temperature sensor to T(KUE) of terminal XD04
f
of the appliance.
HSBC 300 cool (AU) |
19