iNSTAllATiON
Electrical connection
f Route all power cables and sensor leads into the appliance
f
through the cable entry.
f Connect the power cables and sensor leads as detailed
f
below.
Install cables with the following cross-sections in accordance with
the respective fuse protection:
fuse protection
Assignment
B 16 A
Control
18
| HSBC 300 cool (AU)
Cable cross-section
1.5 mm²

11.1 Control voltage

Material losses
!
f Only connect energy efficient circulation pumps ap-
f
proved by us to the pump connections.
XD03.1
Control terminal
XD03.2
Control terminal
XD03.3
Control terminal
XE03
Earth terminal, control unit
XD03.1
Control terminal
Power supply
Mains buffer charging pump
220-240 V
XD03.2
Control terminal
HKP
Heating circuit pump
MKP
Mixer circuit pump, heating circuit 2
Note
At terminals XD03.2 HKP/MKP, you can install a tempera-
ture limiter for the underfloor heating system by remov-
ing the jumper between L and 2.
XD03.3
Control terminal
Mixer
Mixer, servomotor, heating circuit 2
UV
Diverter valve, heating/DHW
www.stiebel-eltron.com