General Information

IMPORTANT SAFETY NOTICE

This appliance has a ceramic Fire-bed arrangement; this contains Refractory
Ceramic Fibres, which are man-made vitreous silicate fibres. Excessive
exposure to these materials can cause irritation to eyes, skin and respiratory
organs. Hence we recommend that when handling these materials the release
of dust should be kept to a minimum. During installation and servicing we
recommend that a HEPA filtered vacuum be used to remove any dust and
soot in and around the fire. If any of the ceramic fire-bed components need
to be replaced we recommend that the removed parts be sealed in a heavy-
duty polythene bag, and be labelled as RCF waste. RCF is not "Hazardous
waste" and can be disposed of at a licensed tipping site for the disposal of
industrial waste.
The appliance incorporates a permanent pilot. This is located on the front
of the burner, and must not be adjusted by the installer. This system must
not be put out of operation, and if any parts require changing, only original
manufacturer parts shall be used.
This appliance is designed to be used either Natural or LPG gas however, each
individual appliance is only capable of running off the type of gas specified at
the time of purchase. It is important to note that once a type of gas has been
specified the fire cannot run off any other type. The type of gas that your fire is
capable of burning is stated on the data information panel.
This appliance has been designed, tested and approved to meet standards in
place for product use, performance and safety. Installation of your appliance
must comply with current building regulations. It is therefore recommend that
a registered gas installer be employed for this task. The engineer will provide
you with information about the safety limits of the installation and should fix a
notice plate in a place where it can be readily seen.
This appliance is designed as a decorative heating device and consequently
all body parts become very hot in use. Except for the control knob and control
access door, which are designed to stay cool, all other parts are working
surfaces and should not be touched.
The front of this appliance incorporates a decorative Log Guard, It does not
give full protection for young children, the elderly or infirm, extra protection
should be considered for these conditions conforming to BS 6539 or BS 6778.
The appliance is not fitted with a functional integral guard. In normal use,
consideration should be given to the use of an additional guard, conforming to
the standard above, such that access to the open flame is minimised.
Bearing in mind that the heat given off by this appliance may affect articles
placed close to it, curtains should not be placed within 30cm.
The appliance is not designed as a dryer. It is not therefore recommended that
the appliance be used in such a manner. Do not place any articles within 30cm
of this appliance as this may result in damage to the articles.
The installation must be carried out in accordance with the following regulations:
The Building Regulations issued by the Department of the Environment, the
Building Standards (Scotland) (Consolidation) Regulations issued by the
Scottish Development Department.
BS 1251, BS 5440 part 1, BS 5871 part 3, BS 6461 part1, BS 6891 and BS 8303
In the Republic of Ireland the installation must also conform to the relevant
standards, particularly in regard to flue sizing and ventilation. Refer to
documents IS813, ICP3, IS327 and any other rules in force.
This appliance must be installed in accordance with national regulations
and the rules in force and used only in a sufficiently ventilated space, and is
intended for use on a gas installation with a governed meter.
Before installation, ensure that the local distribution conditions (identification
of the type of gas and pressure) and the adjustment of the appliance are
compatible. The technical specification of this appliance is given on the rear
page of this manual.
The fuel bed or this appliance should not be disturbed, and rubbish or other
fuels must not be thrown onto the fire.
The Chimney should be checked regularly to ensure that all the products of
combustion are entering the flue or canopy, and that there is no excessive
build up of soot. If any soot is found to build up it must be removed as
described in the servicing instructions.
Ventilation must be checked regularly to ensure that it is free from obstruction.
Any debris from any source, or soot formed shall require removal. Please see
servicing section for details.

GENERAL FITTING INFORMATION

Inlet Pipe connection:
½" BSP Compression
Flame monitor:
Permanent Pilot - ODS
Flue connection:
Ø210mm
Appliance mass:
150kg
User control: Variable rotary control inc. Integrated automated ignition, pilot
facility, Flame failure device and Oxygen Depletion Cut-out.
This appliance is intended for decorative purposes.
Before installation of these appliances, the area into which the fire is to be
fitted must be cleared of all debris (including dust), in particular combustible
material.
This appliance is designed to be built dropped from the ceiling.
The builder's ceiling must be constructed of non-combustible material.
The appliance must have a strong attachment to the ceiling surface sufficient
to support the weight of the fire.
The flue must be connected to only one fireplace, and the flue must not vent
more than one appliance (i.e. not shared with a gas back boiler). There must
be no opening in the flue apart from the one that the appliance is installed into,
and the one venting the gases into the air. A suitable terminal may be fitted,
such as class GC1, as the regulations allow.
Any flue damper plates or flue restrictors shall be removed or fixed permanently
in the fully open position.
The chimney must be swept before the appliance is installed and a flue test in
accordance with national regulations carried out.
This appliance has been tested for use with circular flues of a minimum internal
diameter of 200mm (8") and a minimum height of 3m for tested burner.
The flue termination (cowl) must be of a type suitable for use with an inset
Decorative Fuel Effect Fire BS5871 part 3 contains further details.