    The flue system of this stove should only be installed and serviced by a qualified engineer (i.e. Corgi registered engineer). These instructions should be left with the customer for future reference. This Manual Covers the following appliances : · Pictofocus 860 · Pictofocus 1200...
  • Page 3: General Section

    General section IMPORTANT SAFETY NOTICE This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space, and is intended for use on a gas installation with a governed meter. This appliance has a ceramic Fire-bed arrangement; this contains Before installation, check that this appliance is compatible with local Refractory Ceramic Fibres, which are man-made vitreous silicate fibres.
  • Page 4: User Instructions

    User instructions USING THE APPLIANCE WARNING · Without using a mains adapter, battery replacement is recommended VERY IMPORTANT at the beginning of each heating season. · Old or dead batteries should be removed immediately. If left in the unit Read these instructions thoroughly before lighting. the batteries can overheat, leak, and / or explode.
  • Page 5: C. Setting Fahrenheit Or Celsius

    User instructions Figure 01: 8-symbol Display C. SETTING FAHRENHEIT OR CELSIUS E. CHILD PROOF To change between °C and °F, press buttons simultaneously. To activate press buttons simultaneously. displayed NOTE: Choosing °F results in a 12 hour clock. handset is rendered inoperable, except for the Choosing °C results in a 24 hour clock.
  • Page 6: G. Designated Low Fire And High Fire

    User instructions Handset One-Button Operation TO TURN OFF FIRE (Default Setting) · Press Handset button until two short beeps and · Press a blinking series of lines confirms the start button to turn OFF. sequence has begun; release button. · Main gas flows once pilot ignition is NOTE: A new ignition is possible after the OFF confirmed.
  • Page 7: H. Countdown Timer

    User instructions H. COUNTDOWN TIMER J. THERMOSTATIC MODE ON/SETTING: 1. Press and hold button until displayed, Press button. displayed, preset and hour flashes. temperature displayed briefly, and then room 2. To select hour press button. temperature displayed. 3. To confirm press button.
  • Page 8: L. Auxiliary Feature

    User instructions Default settings: NOTE: Either continue to PROGRAM 2 and set on and off times or stop ON TIME (Thermostatic) TEMPERATURE: 21 °C (70 °F) programming at this point, and PROGRAM 2 remains deactivated. OFF TIME TEMPERATURE: “ ” (pilot flame only) NOTE: PROGRAM 1 and 2 use the same on (Thermostatic) and off and Daily Timer ( , , , , , ,  ...
  • Page 9: Manual Turn Off

    User instructions MANUAL TURN OFF In the event that the appliance needs to be turned OFF manually, for instance, if the remote control is lost or the batteries become totaly flat, the control valve must be accessed and the switch flipped to OFF (marked “0”).
  • Page 10: Installer Section

    Installer section INSTALLATION Before beginning the installation, check that the details on the rating plate correspond to the gas type and pressure to which the appliance will be connected. A. VENTILATION Balanced Flue appliances can be installed into a house without the need for additional ventilation.
  • Page 11: Terminal Locations Wall Mounting

    Installer section C. TERMINAL LOCATIONS WALL MOUNTING Dimension Terminal Locations Distance (mm) Directly below an opening, air brick, opening window, etc. Above an opening, air brick, opening window, etc. Adjacent to an opening, air brick, opening window, etc. Below gutters, soil pipes or drain pipes Below eaves Below balconies of car port roof From a vertical drain pipe or soil pipe...
  • Page 12: Terminal Roof Locations

    Installer section D. TERMINAL ROOF LOCATIONS B. GAS CONNECTION “Distance” = minimum distance required for positioning of the outlet to It is important to ensure that all pipe work installed is fitted in accordance avoid adverse effects with respect to: with BS6891 and is capable of supplying sufficient gas flow and pressure to meet the minimum pressures Technical section of this manual.
  • Page 13: Arranging The Ceramic Fire-Bed

    Installer section ARRANGING THE CERAMIC FIRE-BED Place the remaining five logs as shown in the picture below, i.e. the logs are placed so that one end of each log reaches to the front of the fire, and the other end rests on top of the large log at the rear of the fire. Only the ceramics supplied with this appliance are to be used.
  • Page 14: Pebble Arrangements

    Installer section D. PEBBLE ARRANGEMENTS F. PEBBLE ARRANGEMENTS - LPG GAS Place the Mat on top of the burner such that all the holes on the mat align Place two of the Pebbles, one at each end of the burner, against the firebox with the holes on the burner top plate.
  • Page 15: Servicing Instructions

    Servicing instructions TROUBLESHOOTING The following outlines only the minimum work that should be performed on an annual basis. This service work, like any other work on the appliance, must only be done by a qualified and competent engineer who is CORGI registered.
  • Page 16: Technical Informations

    Technical informations APPLIANCE DIMENSIONS PICTOFOCUS 860 PICTOFOCUS 1200...
  • Page 17: Pictofocus

    IE, IT, PT PT, SE Efficiency Class Nox Class Pilot Burner (SIT OP) 0.977.113 0.977.113 0.977.113 0.977.113 0.977.113 0.977.148 Pictofocus 860 Nominal Input (Gross kW) 10,5 10,5 10,5 / 10 Gas Rate (max. m3/hr) 1,073 1,073 1,073/1,117 1,073 1,117 0,312...
  • Page 18: Pictofocus

    3 Impasse Claque Patin F - 34380 Viols le Fort declares that the FOCUS independent gas fired convection heaters described here are in accordance with the appliances described in the EC-Type Examination Certificate No. UK-LHD-0359-0657R1 delivered by INTERTEK and comply with the essential requirements applicable to EN 613 :2001 + A1 :2008 and Regulation UE 2016/426.
  • Page 19 Note...
  • Page 20 Atelier dominique imbert S.A.S. au capital de 102 355 euros 34380 Viols-le-Fort France Tel. : 00 33 (0)4 67 55 01 93 Fax. : 00 33 (0)4 67 55 77 77 Web : www.focus-creation.com Email : info@focus-creation.com V. 01 - July 2017...