User instructions

EMERGENCY GAS ISOLATION
In the event of a gas leak or if gas is smelt, the appliance must be isolated.
This is done by turning OFF the gas at the Isolation Tap. This Isolation Tap
is located in the foot of the appliance, at the rear.
FIRST TIME OF OPERATION
Before igniting the appliance, ensure that all packaging, safety stickers
and any protective wrapping have been removed, and that the glass has
been cleaned, including all fingerprints from the glass.
Ensure that the room is adequately ventilated the first time that the
appliance is ignited; we would recommend opening windows if possible.
Run the appliance at full setting for a few hours so that the paint gets an
opportunity to fully cure. During this period it is possible for some fumes
and vapours to be given off. We would recommend keeping children and
pets out of the area at this time.
OPERATING INSTRUCTIONS
A. GENERAL NOTES
NOTICE
Wiring of valve and receiver must be completed before starting ignition.
Failure to do so could damage the electronics.
Batteries – Handset
· Low battery indicator on handsets.
Batteries – Receiver
· Low battery indication: frequent beeps for 3 seconds when motor turns.
· An AC mains adapter may be used instead of batteries.
· The module for fan speed control and light/dimmer includes mains
power together with batteries in the receiver for automatic backup in
case of power outage.
WARNING
· Without using a mains adapter, battery replacement is recommended
at the beginning of each heating season.
· Old or dead batteries should be removed immediately. If left in the unit
the batteries can overheat, leak, and / or explode.
· Do NOT expose batteries (including during storage) to direct
sunlight, excessive heat, fire, moisture, or severe impact. Each of these
conditions can cause the batteries to overheat, leak, and / or explode.
· Batteries must be kept within their recommended temperature limits.
(Ambient battery temperature range: 32 °F to 131 °F [0 °C to 55 °C].)
· New and old batteries and different brands of batteries should not be
used together. Mixing of various batteries can cause the batteries
to overheat, leak, and / or explode.
Software Version
Press
and
buttons simultaneously. Software version is displayed.
Handset Model Number
Press
and
buttons simultaneously. Handset model number
is displayed.
Deactivate Functions
1. Install batteries. All icons are displayed and flashing.
2. While the icons are flashing, press the relevant function button and hold
for 10 sec.
3. The function icon will flash until deactivation is complete. Deactivation
is complete when the function icon and two horizontal bars are displayed.
NOTE: If a deactivated button is pressed, there is no function, and two
horizontal bars are displayed.
NOTE: Deactivation remains in effect after change of batteries.
Activate Functions
1. Install batteries. All icons are displayed and flashing.
2. To activate a function, press the relevant button and hold for 10 sec.
3. The function icon will continue to flash until activation is complete.
Activation is complete when the function icon is displayed.
The following Functions can be Deactivated / Activated
· CHILD PROOF
· PROGRAM MODE
· THERMOSTATIC MODE (also deactivates PROGRAM MODE)
· ECO MODE
· LIGHT / DIMMER OPERATION
· CIRCULATING FAN OPERATION
· AUXILIARY FEATURE
· COUNTDOWN TIMER
B. SETTING THE ELECTRONIC CODE (First time use only)
Radio Frequency Handset
A code is selected automatically for all Mertik Maxitrol electronics from
among 65,000 codes available. The receiver must be paired with the
handset.
The receiver has to learn the handset code:
Press and hold the receiver's reset button until you hear two (2) beeps. After
the second, longer beep, release the reset button. Within the subsequent
20 seconds press the
button on the handset until you hear two (2) short
beeps confirming the code is set.
NOTE: This is a one time setting only, and it is not required when changing
the batteries In the handset or receiver.