Section 5
IED physical connections
5.1.1.4
5.1.2
5.1.3
44

Residual voltage

Table 18:
Inputs for residual voltage
Terminal
X130-17, 18

Auxiliary supply voltage input

The auxiliary voltage of the IED is connected to terminals X100/1-2. At DC
supply, the positive lead is connected to terminal X100-1. The permitted auxiliary
voltage range (AC/DC or DC) is marked on the top of the LHMI of the IED.
Table 19:
Auxiliary voltage supply
Terminal
X100-1
X100-2

Binary inputs

The binary inputs can be used, for example, to generate a blocking signal, to
unlatch output contacts, to trigger the disturbance recorder or for remote control of
IED settings.
Table 20:
Binary input terminals X110-1...13
Terminal
X110-1
X110-2
X110-3
X110-4
X110-5
X110-6
X110-6
X110-7
X110-8
X110-9
X110-9
X110-10
X110-11
X110-12
X110-12
X110-13
Description
U
0
Description
+ Input
- Input
Description
BI1, +
BI1, -
BI2, +
BI2, -
BI3, +
BI3, -
BI4, -
BI4, +
BI5, +
BI5, -
BI6, -
BI6, +
BI7, +
BI7, -
BI8, -
BI8, +