2.
Connect the Motor Power Cable (K4) to the β Series Digital Servo Amplifier
CAUTION
Make connections to the CX-11 connector carefully. This connector is not keyed. Double-
check your connections before applying power. Incorrect connections could result in
equipment malfunction or damage. Amplifier versions later than revision G have keyed
connectors.
Table 9: K4 Cable –  Series Motor Cable Examples
Servo Motor Type
 0.5/3000
 1/3000,  2/3000,  3/3000, and
 6/2000
 C12/2000
M 0.5/5000
M 1/5000
Figure 14: Connecting the  Series Digital Servo Amplifier Terminal Strip
System Overview
A.
The size of the motor ordered for your system determines the motor power cable
(K4) you must use. You can choose to purchase prefabricated cables or to build
custom cables. Refer to the  Series Control Motor Descriptions Manual, GFZ-
65232EN, for information about custom cables or installation for conformance
to CE mark. The amplifier end of the prefabricated motor power cable is
constructed to connect to terminal block CX11-3 on the amplifier.
K-4 Motor Cable Part Number
IC800CBL067
IC800CBL068
CF3A-2MPB-0140-AZ
CP8B-1WPB-0140-AZ
CP8B-1WPB-0140-AZ
Chapter 2
Jan 2020
Cable Description
14 Meter
14 Meter
14 Meter
14 Meter
14 Meter
30