GFK-1742F
Table 67: Axis 3 Variables
Local Logic Variable Name
FacePlate I/O
Strobe1_Level_3
Strobe2_Level_3
Positive_EOT_3
Negative_EOT_3
Home_Switch_3
Digital_Output1_3 *
Digital_Output3_3 *
Analog_Input1_3
Analog_Input2_3
Control Variables
Reset_Strobe1_3
Reset_Strobe2_3
Status Variables
Error_Code_3
Actual_Position_3
Strobe1_Position_3
Strobe2_Position_3
Actual_Velocity_3
Axis_OK_3
Position_Valid_3
Strobe1_Flag_3
Strobe2_Flag_3
*
Note:
Local Logic Variables
These Digital Outputs must be configured for Local Logic control in Hardware Configuration
in order to be write-able by Local Logic.
For Axis 3, the DSM314 Version 2.0 only supports the variables in Table 67.
Attribute
Read Only
Read Only
Read Only
Read Only
Read Only
Write Only
Write Only
Read Only
Read Only
Write Only
Write Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Chapter 13
Jan 2020
Size
Bit Operand
Bit Operand
Bit Operand
Bit Operand
Bit Operand
Bit Operand
Bit Operand
Signed 16 Bits
Signed 16 Bits
Bit Operand
Bit Operand
Unsigned 16 Bits
32 Bits
32 Bits
32 Bits
32 Bits
Bit Operand
Bit Operand
Bit Operand
Bit Operand
316

Advertisement

Table of Contents
loading

Table of Contents