3. RS-232 connecting device cable wiring
diagram
1. [Scale: Local Purchase]
1) Data transmission format
- 7bits ASCII code
- Even parity
- One stop bit
- Rate:9600
asynchronous
Their datas are fixed by ECR.
2) Pin-outs
(Scale)
Pin No.
1 Ground
:
2 SD
:
3 RD
:
4 RS
:
5 CS
:
6 DR
:
3) Protocol
(ECR)
Command
<Command>
W
Scale status byte format:
b7
b6
b5
b4
Parity
Always
Net WT.
Center
bit
=1
=1
of
(Even)
zero
=1
(ECR)
Pin No.
: 1
: 2 RD
: 3 SD
: 4
: 5 GND
: 6 DSR
: 7 RTS
: 8 CTS
: 9
(Scale)
Response
<Response>
<STX>0XX.XX<CR> ;Lb
<STX>XX.XXX<CR> ;Kg
(Error)
<STX>?<status byte><CR>
b3
b2
b1
b0
Outside
Under
Out of
Motion
zero
zero
range
=1
capture
=1
=1
range
=1
2. [Coin dispenser: by Telequip Corporation]
1) Data transmission format
- 7bits ASCII code
- One start bit
- Even parity
- One stop bit
- Rate:9600
asynchronous
Their datas are fixed by ECR.
2) Pin-outs
(C/D)
Pin No.
1
:
2 RD
:
3 SD
:
4
:
5 GND
:
3) Protocol
Dispense coins
(ECR)
EOT
"C"
<STX>XX<ETX><cc>
XX:
ten' s+one' s
CC: cents
(ECR)
Pin No.
: 1
: 2 RD
: 3 SD
: 4
: 5 GND
: 6 DSR
: 7 RTS
: 8 CTS
: 9
(C/D)
status
ACK
or
status
NAK