3.3 Datasheet
Model
Input Data (DC)
Recommended Input Power Range (W)
Max. DC input (Vdc)
Max. Input Short-circuit Current (A)
Operating Range (Vdc)
Max. Input Continuous Current (A)
MPPT Voltage Range (Vdc)
Output Data (AC)
Normal Voltage (Vac)
Frequency (Hz)
Current (Max. Continuous) (A)
Power (Max. Continuous) (W)
Power Factor Range
Total Harmonic Distortion
Maximum Units Per Branch
Efficiency
Peak Inverter Efficiency
EURO Weighted Efficiency
MPPT Efficiency
Nighttime Power Consumption
Features
Communication
Lifetime
Others
Ingress Protection (IP)
Protective Class
Temperature (℃)
Relative Humidity
Overvoltage Category
Inverter Isolation
Dimensions
4.Packing checklist
4.1 Accessories
After you receive the Envertech microinverter, please check if there is any damage on the carton,
and then check the inside completeness for any visible external damage on the microinverter and
accessories. Contact your dealer if anything is damaged or missing.
5
EVT1200
(180W~400W)*4
60V
15A
16V~60V
12A*4
22V~48V
220V/230V
50Hz
5.90A
1200W
+/-0.90
<3%
5 Units (12AWG Cable)
95.6%
95%
99.9%
<100 mW
PLCC(Power Line Carrier Communication)
25 Years
IP 67
Class I
-40℃ to +65℃
0%~98%
OVC III (AC Main), OVC II ( PV)
□
Non-isolated
High Frequency Isolated
316.5mm x 189mm x 46mm
4.2 Product Description
C
A
D
Operating range (Vdc):
18V~54V
Normal Output Voltage (Vac):
220V/230V
MPPT Voltage Range (Vdc):
24V~45V
Current (Max. continuous) (A):
5.45A
Max. DC input (Vdc):
54V
Nominal Output frequency:
50Hz/60Hz
Max. input current (A):
12Ax4
Power factor:
>0.99
Isc PV (Absolute Max.) (A) :
15A
Maximum units per branch:
5
Enclosure rating:
IP67
Protective class:
I
Power (Max. continuous) (W):
1200W
Overvoltage category:
III[Mains],II[PV]
PV Microinverter
Operating temperature range:
-40 ℃ ~ +65 ℃
Model : EVT1200
User Identification Number :
Zhejiang Envertech Corporation Ltd.
www.envertec.com
B
B
4.3 Further information
If you have any further questions concerning accessories or installation, please check our website
www.envertec.com or send an email to tech@envertec.com.
5. Planning of Microinverter Installation
5.1
Symbols on Inverter
Symbol
Description
Dangerous electrical voltage
This device is directly connected to public grid, thus all work related to
theinverter shall only be carried out by quali ed personnel.
NOTICE, danger!
This device directly connected with electricity generators and public grid.
Danger of hot surface
The components inside the inverter will release a log of heat during
operation. DO NOT touch aluminum casing during operating.
An error has occurred
Please go to Chapter 8 "Trouble Shooting" to repair the error.
This device SHALL NOT be disposed of in residential waste
Please go to Chapter 10 "Recycling and Disposal" for proper treatments.
No unauthorized perforations or modi cations
Any unauthorized perforations or modi cations are strictly forbidden. If any
defect or damage (device/person) is occurred, Envertech shall not take any
responsibility for it.
Item
Description
A
DC connectors
B
AC connector
C
Wall bracket hole
D
Grounding hole
6
Need help?
Do you have a question about the EVT1200 and is the answer not in the manual?