Switch 4005 Fan Trays; Fan Tray Description - 3Com 4005 Installation And Maintenance Manual

3com 4005: install guide
Hide thumbs Also See for 4005:
Table of Contents

Advertisement

6

Fan Tray Description

S
4005 F
WITCH
This chapter describes how to remove and install a fan tray (Model Number
3C16823) from the Switch 4005 chassis. The main sections are titled as follows:
Fan Tray Description
I
Removing a Fan Tray
I
Installing a Fan Tray
I
Troubleshooting a Fan Tray
I
The Switch 4005 chassis can contain two fan trays (Model Number 3C16823),
which are installed from the rear of the chassis, as shown in Figure 14.
Figure 14 Fan Trays in the Switch 4005 Chassis
Fan tray
(in slot 1)
Heat is produced while the Switch 4005 is operating. To cool the chassis, the fan
trays pull in cooler ambient air from vents in the module faceplates and then expel
the hot air through vents in the rear of the fan trays.
The power supplies also contain small fans. Their fans pull air from side vents in
the chassis and expel hot air through vents in the rear of the power supplies.
Fan tray failure or ambient air that is too hot will eventually cause the Switch 4005
to power off. Ensure that your site meets the requirements described in Chapter 3.
The chassis does not contain temperature sensors. However, a trap is sent to the
management application when one or more fans in a fan tray is not operating
normally.
T