Compressor Frequency Limitation By Outdoor Temperature - Fujitsu ABYG36KRTA Service Manual

Ceiling type
Hide thumbs Also See for ABYG36KRTA:
Table of Contents

Advertisement

1-5. Compressor frequency limitation by outdoor temperature

The minimum compressor frequency is limited by outdoor temperature as below.
• Cooling/Dry mode
Model name
AOYG36KRTA
AOYG45KRTA
1-5. Compressor frequency limitation by outdoor temperature
K zone
52°C
J zone
50°C
I zone
46°C
H zone
31°C
G zone
21°C
F zone
13°C
E zone
7°C
D zone
2
°C
C zone
-5
°C
B zone
-10°C
A zone
Outdoor temperature zone
A zone
B zone
C zone
D zone
E zone
F zone
G zone
H zone
I zone
J zone
K zone
A zone
B zone
C zone
D zone
E zone
F zone
G zone
H zone
I zone
J zone
K zone
- (04-5) -
Limitation of compressor
frequency
55 rps
52 rps
47 rps
39 rps
33 rps
25 rps
18 rps
20 rps
20 rps
21 rps
24 rps
50 rps
47 rps
40 rps
30 rps
22 rps
20 rps
16 rps
16 rps
17 rps
23 rps
28 rps