1-5. Compressor frequency limitation by outdoor temperature

The minimum compressor frequency is limited by outdoor temperature as below.
• Cooling/Dry mode
Model name
ROG09KMCDN
ROG12KMCDN
ROG14KMCDN
1-5. Compressor frequency limitation by outdoor temperature
F zone
38°C
E zone
19°C
D zone
10°C
C zone
0°C
B zone
-10°C
A zone
Outdoor temperature zone
A zone
B zone
C zone
D zone
E zone
F zone
A zone
B zone
C zone
D zone
E zone
F zone
A zone
B zone
C zone
D zone
E zone
F zone
- (04-6) -
Limitation of compressor
frequency
38 rps
38 rps
36 rps
31 rps
1 rps
30 rps
34 rps
34 rps
34 rps
34 rps
12 rps
18 rps
32 rps
32 rps
32 rps
32 rps
14 rps
22 rps
1. Compressor frequency control