Igniters per fireplace
NOTICE
i
i
In closed fire rooms, it might happen that gas accumulates in the area around the fireplace
after 5 failed ignition attempts of the igniter; this gas may burn off in an uncontrolled way.
After 5 failed ignition attempts in succession, the ventilator in C3 is switched to maximum
power for 1 minute to remove any gas residues from the fire room. Afterwards, the alarm
of the igniter can be reset using the reset button on the cabinet or in the software.
For each fireplace there is one igniter that is started via
this module and that can be reset following an error.
Start: Switches on the pilot flame.
Stop: Switches off the pilot flame.
Flashing green: Pilot flame is started.
Lit green: Pilot flame burning
flashing red: New alarm present
Lit red: Acknowledged alarm present
Reset: Reset the igniter after an alarm. The button is only active when there is an
alarm.
Selecting the ignition
The following ignition options can be selected via
the pull-down menu:
Start igniter via the remote control
Start the igniter via the touchpanel
The ignition can only be started via the selected device (remote control or touchscreen).
Edition 03 / 69 06 898
FTS 8000
Operation
Fig. 65 Igniters
Fig. 66 Ignition selection