Download Print this page

Yale 7130F Series Installation Instructions Manual page 3

Mortise exit devices

Advertisement

1. Mark Door
Locate and Mark Horizontal and Vertical Reference
Centerlines as shown.
LHR door shown
preparation is typical
for both door hands.
Note: Centerline of Lock (cutout)
must match Horizontal Reference
centerline.
2. Prepare Door & Frame
Factory prepared cutouts with field drilled mounting holes are
recommended. If door (lock) and frame (strike) have to be mortised in
the field, do it before continuing (follow instructions on Installation
Template).
Spot and Prepare Mounting Holes As Follows:
A. Locate and tape Trim Template to door.
(See instructions packed with Trim.)
B. Locate "Device Template" aligning VERTICAL REFERENCE
and HORIZONTAL REFERENCE lines on door and template.
Tape template to door face.
(1) slot 1/2" (12.7) Dia. x 1" (25.4) on centers thru inside door face and
(2) Device holes for 1/4-20 Machine Screws*, or for 3/8" (9.5) Dia. Sex
nuts and Bolts.
(*) Metal reinforced doors only.
C. Insert lock into mortise, adjust front for door edge (beveled or flat)*.
(2) Lock holes for 12-24 Machine Screws or for #12 Wood Screws.
(*) NOTE: Lock base front has to be field tightened in place, (two screws,
each on lock case top and bottom).
D. Seat strike in frame cutout.
(2) Strike holes for 12-24 Machine Screws, or for #12 Wood Screws.
An ASSA ABLOY Group brand
Finished Floor
DOOR, LOCK AND STRIKE
(ANSI A115.1 BACKSET)
Device Template
3
80-9470-0030-000 (11-18)

Advertisement

loading