Hyperthermia occurs when the internal temperature of the body
reaches a level several degrees above the normal body
temperature of 37°C (98.6°F). The symptoms of hyperthermia
include an increase in the internal temperature of the body,
dizziness, lethargy, drowsiness, and fainting. The effects of
hyperthermia include failure to perceive heat; failure to
recognize the need to exit spa or hot tub; unawareness of
impending hazard; fetal damage in pregnant women; physical
inability to exit the spa or hot tub; and unconsciousness resulting
in the danger of drowning.
WARNING: THE USE OF ALCOHOL OR DRUGS CAN GREATLY INCREASE THE
RISK OF FATAL HYPERTHERMIA IN HOT TUBS AND SPAS.

Lock/Unlock Button

The pump has a 5-minute auto-lock. The LED light will dim out when the pump is
locked (no function is activated). To lock or unlock the pump, place a finger over
the lock/unlock button for 3 seconds.

Power-Saving Timer Button

This is a newly added function, designed to help avoid wasting power by setting
the time and duration of the heating cycle for the spa.
This way, you can enjoy your spa at the time you desire, without needing to
leave the heater on at all times.
STEP 1: Set the heating duration
1. Press the
button unit the
LED starts to flash.
2. Press the
or
button to adjust the heating duration (From 1-48 hours).
3. Press the
button again to confirm the heating duration.
STEP 2: Set the number of hours FROM NOW when the heater will activate
1. After setting the heating duration, the
2. Press the
or
button to adjust the hours until time of activation
(From 0-99 hours).
3. Press
button again or simply touch nothing for 10 seconds to confirm
the setting. The
LED will light steadily, and the countdown to heater activation will
begin.
To modify the timer settings: Press the
Cancel the setting: Press the
NOTE: After setting, the screen flashes the current temperature and time alternately.
NOTE: Timer adjustment (amount of time with the heater ON) may be set from 1 to 48
hours; Reservation time adjustment (the number of hours FROM NOW when the
heater will begin to function) may be set from 0 to 99 hours. If the timer is set at 0 hour, the
heating system will activate immediately.
Note that the timer is one time per use - the user sets the duration of the heating cycle, and
how many hours from now the heating cycle begins. The timer does NOT repeat until reset.
Massage System Button
Use this button to activate the massage system, which has a 30-minute
auto-shutoff feature. The light above the Massage System Button displays red
when activated.
IMPORTANT: Do not run the Massage system when the cover is
attached. Air can accumulate inside the spa and cause irreparable
damage and bodily harm.
NOTE: Heat and massage system work together to create a warm
massage experience.
303021213400_14.0x21.0cm_54124,54130,54149,54155,54176,54187,54190,54295,54297_美规AirJet SPA说明书_
LED starts to flash.
button and use the
or
button to adjust.
button for 2 seconds.

Celsius/Fahrenheit Toggle

The temperature can be displayed in either Fahrenheit or Celsius.

Heat Button

Use this button to activate the heating system. When the light above the heat
button is red, the heating system is activated. When the light is green, the water
is at the set temperature and the heating system is at rest.
NOTE: If the heating system is activated the filtration system will automatically start.
NOTE: After turning off the heating system the filtration system will continue to operate.
Water Filter Button
This button turns the filter pump on and off. The light above the Water Filter
Button displays red when activated.
Temperature Adjustment Buttons
Pressing the Temperature Increase or Decrease buttons will cause the LED to flash.
When it is flashing you can adjust to the desired temperature setting. If you hold these
buttons down the values will rapidly increase or decrease. The new and desired
temperature setting will remain on the LED display for 3 seconds to confirm the new value.
NOTE: The default temperature is 35°C (95°F).
NOTE: Temperature adjustment ranges from 20°C (68°F) to 40°C (104°F).
On/Off Button
Press this button for 2 seconds to active the control panel bottons and the light turns
to green. Press this button for 2 seconds to turn off all currently activated functions.
Power-Saving Timer LED
This LED flashing means you are setting the heating duration. The light will be on
when the heating function starts to work.
This LED flashing means you are setting the number of hours FROM NOW when the
heater will activate. When the light is on, the Power-Saving Timer function is set.
LED Display
Once powered-up the LED displays the current water temperature automatically.
After 72 hours of filtration (without using the power saving timer function),
the pump will hibernate and flash "End" with the current water temperature.
When the pump is hibernating both the heating and water filter functions are
disabled. To re-activate the pump press lock/unlock button for 3 seconds.
NOTE: The water heat rate may change in the conditions below:
• When the outdoor temperature is below 15°C (59°F).
• If the cover is not in position when the heating function is activated.
NOTE: To display the current water temperature, run the filter system for at least a
minute. The water temperature as tested by an external thermometer may vary from the
temperature as displayed on the spa panel by as much as approximately 2°C.