Connecting

5.5 Instructions specific to hazardous area installations

5.5
Instructions specific to hazardous area installations
5.5.1

(Reference European ATEX Directive 2014/34/EU, Annex II, 1.0.6)

The following instructions apply to equipment covered by certificate number SIRA
09ATEX9356X and Sira 09ATEX4357X.
1. For use and assembly and details of marking/coding, refer to the main instructions.
2. The equipment is certified for use as Category 1D, 1/2D and 2D equipment per certificate
Sira 09ATEX9356X and may be used in hazardous zones 20, 21 and 22. The equipment
is also certified for use as Category 3G equipment per certificate Sira 09ATEX4357X and
may be used in hazardous zone 2.
3. This equipment has a maximum surface temperature of 139 °C (in an 80 °C ambient).
Refer to the applicable code of practice for selection of this equipment with respect to
specific dust ignition temperatures.
4. The equipment is certified for use in an ambient temperature range of -40 °C to 80 °C.
5. The equipment has not been assessed as a safety related device (as referred to by
Directive 2014/34/EU Annex II, clause 1.5).
6. Installation and inspection of this equipment shall be carried out by suitably trained and
authorized personnel in accordance with the applicable code of practice.
7. The equipment shall be installed such that the supply cable is protected from mechanical
damage. The cable shall not be subjected to tension or torque. The equipment
manufacturer is not responsible for providing the supply cable.
8. Repair of this equipment shall be carried out by suitably trained and authorized personnel
in accordance with the applicable code of practice.
5.5.2

Special conditions for safe use

SPECIAL CONDITIONS FOR SAFE USE
The 'X' suffix to the certificate number relates to the following special condition(s) for safe
use:
● Parts of the enclosure may be non-conducting and may generate an ignitioncapable level
of electrostatic charge under certain extreme conditions. The user should ensure that the
equipment is not installed in a location where it may be subjected to external conditions
(such as high-pressure steam), which might cause a build-up of electrostatic charge on
non-conducting surfaces.
● The end user must ensure that an ingress protection of at least IP65 is maintained at
each entry to the enclosure by use of a blanking element or cable entry device that meets
the requirements of the protection concepts type 'n' or increased safety 'e' or flameproof
'd'.
● The supply to the equipment shall be rated for a prospective short-circuit current of not
more than 10 kA and shall be protected by a suitably-rated fuse.