Instructions Specific To Hazardous Area Installations; European Directive 2014/34/Eu, Annex Ii, 1.0.6 And Uk Regulation Si 2016/1107 - Siemens SITRANS LR460 Operating Instructions Manual

Radar transmitters
Hide thumbs Also See for SITRANS LR460:
Table of Contents

Advertisement

Connection

5.8 Instructions specific to hazardous area installations

5.8
Instructions specific to hazardous area installations
5.8.1
European Directive 2014/34/EU, Annex II, 1.0.6 and UK Regulation SI
2016/1107
Note
Installation shall be performed only by qualified personnel and in accordance with local
governing regulations.
The following instructions apply to equipment covered by certificate numbers
SIRA 06ATEX9218X and CSAE 21UKEX9088X.
1. For use and assembly, refer to the main instructions.
2. The equipment is certified for use as Category II 1D, 1/2 D & 2D equipment. The Essential
Health and Safety Requirements are assured by compliance with EN 60079-0 and EN 60079-
31.
3. The equipment may be used with dust and fibers with apparatus temperature class T (see
item 4 below).
4. Thermal Data for 7ML5426 Series
5. The equipment has not been assessed as a safety related device (as referred to by Directive
2014/34/EU Annex II, clause 1.5).
6. Installation and inspection of this equipment shall be carried out by suitably trained
personnel in accordance with the applicable code of practice (EN 60079-14 and EN 60079–
17 in Europe).
7. Repair of this equipment shall be carried out by suitably trained personnel in accordance
with the applicable code of practice.
8. Components to be incorporated into or used as replacements in the equipment shall be
fitted by suitably trained personnel in accordance with the manufacturer's documentation.
9. It is the user's responsibility to ensure that a manual override is possible in order to shut
down the equipment, and that protective systems are incorporated within automatic
processes which deviate from the intended operating conditions, provided that this does not
compromise safety.
36
Device category
Permitted ambient temperature at
horn antenna
1D, 1/2D, 2D
–40 °C (–40 °F)≤T
°F)
Permitted ambient temperature
at electronic enclosure
≤+200°C (+392
–40 °C (–40 °F)≤T
amb
°F)
Compact Operating Instructions, 10/2021, A5E32007360-AB
≤+65°C (+149
amb
SITRANS LR460

Advertisement

Table of Contents
loading

Table of Contents