Download Print this page

Bosch AMC2 4W-EXT Installation Manual page 13

Wiegand extension board
Hide thumbs Also See for AMC2 4W-EXT:

Advertisement

41
en | Operating
6
Operating
6.1
Status Display of the AMC2 4W-EXT
Because the AMC2 4W-EXT has no display of its own, the AMC2
4W displays status information about the input and output
settings of the AMC2 4W-EXT.
The selected display mode remains set until the next time the
button is pressed. The order of the display pages is shown in
the following table.
Push
0
1
2
3
3a
3b
3c
4
5
6
| V 2.6 | 2008.12
Display (Example)
V01.00 02.03.07
or
WIEGAND
99999876543210 A
02.06 15:35:15
Dig. IO: ::::::::::::::::
Dig. I1: ::::::::::::::::
Dig. I2: ::::::::::::::::
Dig. I3: ::::::::::::::::
MAC 0010174C8A0C Network device address (MAC)
N AMC-1234-5678
I 192.168.10.18
Installation manual
Description
Software versions and date of
the downloader - every 5 sec.
alternating with the display of
the reader interface.
(= default page)
BOSCH serial number and bus
address:
A = address 1
...
H = address 8
Current date and time
Display of the digital contacts:
the input signals set will be
shown with an extension above
- output signals with an
extension below.
If there are I/O-Boards
connected the signals will be
shown on separate pages.
Network name of the AMC2
IP-address of the AMC2
Bosch Sicherheitssysteme GmbH
AMC2 4W-EXT

Advertisement