B-4
A
B: T
PPENDIX
ECHNICAL SPECIFICATIONS
Power Requirements
Propagation Delay: 5.7 nanseconds/meter
Cabling: RJ-45 plug to RJ-45 plug straight-through for multiport repeater
applications (transmit to receiver crossover cable for two-node network).
FireWire
Electrical specification: N/A
Connector: IEEE P1394
Configuration: N/A
Transmission method: HSSB (High Speed Serial Bus)
Transmission rate: N/A
Environmental
Shipping and Storage Temperature: 0° C to 40° C, 32° F to 104° F
Shipping and Storage Relative Humidity: 0 – 95%, non-condensing
Operating Temperature: 0° C to 40° C, 32° F to 104° F
Maximum Rated Ambient Temperature: 40° C, 104° C
Operating Relative Humidity: 0 – 95%, non-condensing
Voltage (VDC)
Maximum Current (A) Maximum Power Output (W)
12
1.5
5
12 *
3.3
10 *
The 5 and 3.3 VDC outputs "power-share." Since the maximum power
output of the 12 VDC supply is 30 W, the remaining 40 W is shared between
the 3.3 and 5 VDC supplies. If no load in 3.3 V and 12 V limited to 0.6 A,
then 5 V can deliver 12 A.
Input Voltage: 100 - 240 VAC, 50/60 Hz
Maximum Input Current: 1.5 A
30
35
33